2vacon • 6 Filter typesTel. +358 (0) 201 2121 • Fax +358 (0)201 212 205The Vacon NX AC drives comply with the immunity requirements EN/IEC 61800-3; 2004, secondenvironment as standard.Note that the filters RFI-0012-5-IP54 to RFI-0105-5-IP54 are designed to fit mechanically directly tothe corresponding drive. All others are loose and must be connected to the drive separately.2.1.2 RFI filter typesTable 1. RFI footprint filters for drive for drive frame sizes 4-7SuitabilityTable 2. Drive suitability for 200VAC & 500VAC air cooled drives frame sizes 4-7InstallationFigure 2. RFI filter installation principal diagramFilter type code DrawingnumberManufacturer'spart codeRated vol-tage, 3~, 50-60Hz [VAC]Nominalcurrent at50°C [A]DimensionsW x H x D [mm] W[kg] IPclassRFI-0012-5-IP54 70CTC1100857 FS32821-16-99 520 16 128 x 395 x 61.5 2.8 IP54RFI-0031-5-IP54 70CTC1100865 FS32821-42-99 520 42 144 x 490 x 61.5 4.4 IP54RFI-0061-5-IP54 70CTC1100869 FS32821-75-99 520 75 195 x 625 x 90 8.2 IP54RFI-0105-5-IP54 70CTC1100887 FS32821-130-99 520 130 230 x 745 x 100 15.5 IP54200VAC drive Filter 500VAC drive FilterNX_0003-0012 2 RFI-0012-5-IP54 NX_0003-0012 5 RFI-0012-5-IP54NX_0017-0031 2 RFI-0031-5-IP54 NX_0016-0031 5 RFI-0031-5-IP54NX_0048-0061 2 RFI-0061-5-IP54 NX_0038-0061 5 RFI-0061-5-IP54NX_0075-0088 2 RFI-0105-5-IP54 NX_0072-0105 5 RFI-0105-5-IP54# Reference # ReferenceA Keypad C Power unitB Control D RFI filter7119_00ABCDL1L2L3U/T1V/T2W/T3DC-DC+/R-R-