201REVO-E Heat pump 2 Technical specifications2 Technical specificationsThe technical specifications, provided that there are nolimit values given, comply with the standard tolerances forair-conditioning systems of ±10% for an ambient temper-ature of +20° C and nominal voltage.Table 201 Technical specifications1 ) Tambient = 35 °C, Tcabin = 40 °C2 ) Tambient = 5 °C , Tcabin = 20 °C3 ) Version installed two times in articulated vehicleREVO-E heat pump REVO-E HP+ REVO-E HP11123865_ 3 11120816_Application Volvo E-Bus 2ndGeneration(from 2018)Volvo E-Bus 1stGeneration(till 2018)Operating range heat pump [°C] ≥ -5 ≥ 3Cooling capacity [kW] 1 25Heating capacity in heat-pump-mode [kW] 2 16Heating capacity coolant circuit [kW] 40Air volume [m³/h] 6960Current consumption [A](24 V DC)maximum (all 100 %) 85nominal (condenser 80%, evaporator 70%) 55regulated(the temperature in the passenger compartment is at setpoint)11Current consumption [A](600 V DC)maximum (compressor speed at 50Hz) 22regulated(the temperature in the passenger compartment is at setpoint 25°C - ambient temperature 35 °C, reduced com-pressor speed)9Weight [kg] 272Dimensions (length x wide x height) [mm] 2802x2091x406Operation voltage range [V DC] 450-750Refrigerant R134AFilling capacity w/o front box[kg] 5Filling capacity with front box [kg] 5.5