14FAN INPUT POWERProduct titlesVallox 101 MV RVallox 101 MV LProduct numbers41021894102197HVAC code79121197912120Additional heatingradiator–Air volumes Supply airExtract air90 l/s, 324 m3/h, 100 Pa98 l/s, 353 m3/h, 100 PaFans Supply airExtract air0.115kW, 0.9A EC0.115kW, 0.9A ECElectrical connection 230V, 50Hz, 8.3A (powerplug)Operating efficiencies Annual efficiencySupply air efficiencySpecific Fan Power (SFP)70% A82%1,0 (38dm3/s)Enclosure protectionclassIP34 Filters Supply airExtract airG4 and F7G4Post-heating radiator Power, 1500 W Heat recovery bypass AutomaticPreheating radiator – Weight 50kgDimensions (width xheight x depth)598x447x596mmSound power level in the supply air ductby octave band Lw, dBSound power level in the extract air ductby octave band Lw, dBAdjustment position 4% 14% 22% 33% 41% 50% 55% 66% 75% 100% 4% 14% 22% 33% 41% 50% 55% 66% 75% 100%Air flow dm3/s (l/s) 8.6 15 16.9 37.7 45.1 53.5 57.3 67.4 73.3 82.3 11.3 24.4 34.3 45.6 55.6 65.9 72.6 83 91.5 99.2Air flow m3/h 30.96 54 60.84 135.72 162.36 192.6 206.28 242.64 263.88 296.28 40.68 87.84 123.48 164.16 200.16 237.24 261.36 298.8 329.4 357.12Mediumfrequencyof theoctaveband Hz63 56 58 63 67 70 72 75 77 79 80 62 53 56 58 61 64 67 68 70 71125 52 62 63 65 67 69 71 74 76 78 52 58 58 61 64 67 69 70 73 74250 44 52 57 64 70 66 70 71 72 74 35 45 50 57 60 60 62 62 62 63500 40 49 53 58 61 64 65 69 71 74 27 34 40 44 48 51 53 55 57 621000 32 41 46 51 55 58 60 63 67 68 16 23 28 33 36 39 42 44 46 482000 24 34 40 47 51 55 57 61 63 65 14 17 23 29 32 36 38 41 43 444000 23 25 31 38 43 48 50 55 57 60 16 16 17 21 24 28 31 34 36 398000 21 21 23 30 35 41 44 51 53 56 20 20 20 20 20 21 22 24 26 29LW, dBLWA, dB(A)58 64 67 71 74 75 78 80 82 84 62 59 61 64 67 69 72 73 75 7741 50 54 60 64 65 67 70 73 75 39 43 45 50 54 55 57 58 59 62Sound pressure level, in decibels (A) coming through the envelope from the room in which the unit is installed (10m2 sound absorption)ADJUSTMENT POSITION / AIR FLOWS (supply/extract)Adjustment position 4% 14% 22% 33% 36% 50% 55% 66% 75% 100%Air flow dm3/s (l/s) 13/15 21/24 29/32 39/41 43/46 55/58 60/62 69/72 76/78 84/85Air flow m3/h 46.8/54 75.6/86.4 104.4/115.2 140.4/147.6 154.8/165.6 198/208.8 216/223.2 248.4/259.2 273.6/280.8 302.4/306LpA, dB (A) 21 26 30 36 38 42 43 46 48 50Input power (total) (W)Air flow (max) (dm3/s)SFP =SFP rate (Specific Fan Power)recommended value <1.8 (kW m3/s)41%33%50%55%66%75%100%14%4%22%501001502002503003500 10 20 30 40 60 70 80 90 100SFP: 1,05036 72 1080 144 180 216 252 288 324 360(l/s)SFP: 1,5BASFP: 1,85010015020025036 72 1080 144 180 216 252 288 324 360BA4% 14% 22%33% 41%50%55%66%75%100%Volume flow ratePower (W)SUPPLY/EXTRACT AIR VOLUMESSOUND VALUESTECHNICAL SPECIFICATIONSVolume flow rate (dm3/s)Pressure loss in ducts. Total pressure (Pa)extract airsupply airTECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONS