VEGACAP 66 is a compact instrument, i.e. it can be operatedwithout external evaluation system. The integrated electronicsevaluates the level signal and outputs a switching signal. Withthis switching signal, a connected device can be operateddirectly (e.g. a warning system, a PLC, a pump etc.).The exact range of the power supply is stated in the Technicaldata in the Supplement.3.3 AdjustmentThe probe can be adapted to the dielectric constant of theproduct directly on the electronics module.A switching command can be triggered when the probe iscovered or laid bare.On the electronics module you will find the following indicatingand adjustment elements:l signal lamp for indication of the switching condition (green/red)l Potentiometer for switching point adaptationl DIL switch for measuring range selectionl DIL switch for mode adjustment3.4 Storage and transportYour instrument was protected by packaging during transport.Its capacity to handle normal loads during transport is assuredby a test acc. to DIN 55439.The packaging of standard instruments consists of environ-ment-friendly, recyclable cardboard. For special versions, PEfoam or PE foil is also used. Dispose of the packaging materialvia specialised recycling companies.l Storage and transport temperature see "Supplement -Technical data - Ambient conditions"l Relative humidity 20 ... 85 %Power supplyPackagingStorage and transport tem-peratureVEGACAP 66 - with relay output 9Product description30020-EN-050920