5 Connecting to power supply5.1 Preparing the connectionAlways keep in mind the following safety instructions:l Connect only in the complete absence of line voltagel If overvoltage surges are expected, overvoltage arresters shouldbe installed according to Foundation Fieldbus specificationTip:We recommend VEGA overvoltage arrester B63-32.In hazardous areas you must take note of the respective regulations,conformity and type approval certificates of the sensors and powersupply units.The instrument requires a operating voltage of 9 … 32 V DC.Operating voltage and the digital bus signal are carried on the sametwo-wire connection cable. Power is supplied via the H1 power supply.Connection is carried out with screened cable according to Fieldbusspecification.Use cable with round cross-section. A cable outer diameter of 5 … 9 mm(0.2 … 0.35 in) ensures the seal effect of the cable gland. If you areusing cable with a different diameter or cross-section, exchange theseal or use a suitable cable gland.Make sure that the entire installation is carried out according to theFieldbus specification. In particular, make sure that the bus isterminated with suitable terminating resistors.On the instrument with cable entry ½ NPT and plastic housing there isa metallic ½" threaded insert moulded into the plastic housing.Caution:No grease should be used when screwing the NPT cable gland orsteel tube into the threaded insert. Standard grease can containadditives that corrode the connection between threaded insert andhousing. This would influence the stability of the connection and thetightness of the housing.With systems with potential equalisation, connect the cable screendirectly to ground potential at the power supply unit, in the connectionbox and at the sensor. The screen in the sensor must be connecteddirectly to the internal ground terminal. The ground terminal outside onthe housing must be connected to the potential equalisation (lowimpedance).Safety instructionsVoltage supplyConnection cableCable gland ½ NPTCable screening andgrounding14 VEGAFLEX 65 • Foundation Fieldbus5 Connecting to power supply31848-EN-120329