35GA 4000ACICOPERATING MANUALEDITION 06/ 2011 PART NO. DOC23129566.1 SHUTTING DOWN AND CLEANING1. Relieve the pressure of gun and unit.2. Secure gun (Remove the control air hose).3. Connect up the supply of cleaning solvent.4. Remove AirCoat nozzle and clean separately (see chapter 5.4.3).5. Pressurize the cleaning supply to approx. 4 MPa; 40 bar; 580 psi and thoroughly flushthe spray gun.6. Relieve the pressure of gun and unit.7. Secure gun (Remove the control air hose).8. Clean external the spray gun with a cleaning agent recommended by the manufacturerand dry with a cloth or blow gun.SIHI_0064_GBCAUTIONSolvent in air conduit!Problems