4A-350 HZ PORTABLE GENERATORS G2.1A/G2.1AE 4A230V 230V4.6 Control PanelThe generator is protected by a 10 amp circuit breaker(a) located on the control panel.The circuit breaker protects the generator from severeoverloads or short circuits. If the circuit breaker opens,turn the engine off immediately and determine the causebefore restarting. Check the appliances and tools at-tached to the generator for defects and make sure theirpower requirements do not exceed the power rating ofthe generator.When the circuit breaker opens, the breaker button willpop out. To reset circuit breaker, push button in.Depending on model, the generator will have one of thefour styles of receptacles, the Danish IP44 type (b), theSwiss IP X4 type (c), the France/Belgium IP44 type (d),or the Schuko IP44 (CEE 7) type (e).Note:Enlargements of receptacles show protectivecovers removed for identification purposes only. Neverremove protective covers.4.7 Earth-leakage Circuit BreakerGenerator model G2.1AE is equipped with an earth-leakage circuit breaker. The circuit breaker is currentoperated and shuts off the power to the receptacles whena ground fault of 30 milli-Amps or greater occurs in thegenerator or to a piece of equipment attached to thegenerator. The circuit breaker is located on the oppositeside of the generator as the control panel.The circuit breaker should be tested for proper operationevery time the generator is used.To test the earth-leakage circuit breaker:Start the generator. Place main circuit breaker in closedposition. Push in TEST button (g). The circuit breakerlever will lower to the open position (f2 ). Power is now offat both receptacles. If the lever does not lower, the circuitbreaker is not working. Do not use the generator until theproblem can be corrected. To restore power to thereceptacles, raise the circuit breaker lever to the closedposition (f1 ).If the circuit breaker lever lowers to the open positionduring operation, stop the generator and check it andequipment for defects. Repair all defects before operat-ing generator.1020SD80TESTgf 1f 2b cControl Panela Main circuit breaker - 10 Amp.b Danish IP44 style receptacle.c Swiss IP X4 style receptacle.d France/Belgium IP44 style receptacle.e Schuko IP44 (CEE 7) style receptacle.ad e1031SD43