Maintenance GP 2500Awc_tx000448gb.fm 326.8 Adjusting Engine SpeedSee Graphic: wc_gr000032Generators require a fixed engine speed to maintain the correctvoltage. Engine speed is controlled by a governor which automaticallyadjusts to varying loads on the engine to maintain a constant speed.There is no throttle control.To set the engine to the proper speed:Turn the speed adjusting screw (b) in or out to obtain a no-load speed.See Technical Data.CAUTION: Setting the engine speed too high or too low may damagetools and other appliances attached to the generator.6.9 StorageBefore storing the generator for a long period of time:6.9.1 Close the fuel valve and remove and empty the sediment cup or fuelstrainer.6.9.2 Disconnect the fuel line from the carburetor. Place open end of fuel lineinto a suitable container and open fuel valve to drain fuel from tank.Gasoline is extremely flammable. Drain the fuel tank in a well-ventilated area. DO NOT drain the fuel tank in an area with flames orsparks.6.9.3 Loosen the drain screw on the carburetor and drain any remaining fuelfrom the carburetor.6.9.4 Change the engine oil.6.9.5 Remove the spark plug and pour approximately 30 ml (1 ounce) ofclean engine oil into the cylinder. Crank the engine a few turns todistribute the oil to the inside of the cylinder walls.6.9.6 Pull the starter rope slowly until resistance is felt and leave the handlein this position. This ensures that the intake and exhaust valves areclosed.6.9.7 Store the generator in a clean, dry area.WARNING