51Press:02030204ProgrammingSpecial cooling valveAnswer YES is there is a separate water valveused for cooling. If the answer is NO, the standardcold water inlet is used.Gentle actionAnswer YES if the machine is to operate on gentleaction during cooling. The machine will operate onnormal action if the answer is NO.TimesCold water is supplied in stages by the water valveopening and closing according to a particularpattern. The time for an opening or closingsequence is 30 seconds. This time is permanentlyprogrammed and cannot be changed. All that canbe programmed is the ratio between open andclosed valve.The time the valve is open (ON time) can beprogrammed separately between 1 and 15seconds. The valve is closed during the remainingtime up to 30 seconds. The ON time isprogrammed separately within two temperatureranges: 212-158°F (100-70°C) and 158°F (70°C)— final temperature.The rate of temperature reduction is monitoredwithin the 212-158°F (100-70°C) range. If the ONtime is selected so that the water temperature inthe drum decreases by more than 7°F (4°C)/minute, the valve is closed so that this value is notexceeded.The final temperature can between 77-140°F(25-60°C) be programmed.PROGR.MODE SELECT SEQUENCE COOL DOWN 01PAUSE WITH BUZZER Y/N NSEPARATE COOL DOWN VALVE Y/N NGENTLE ACTION Y/N NPROGR.MODE SELECT SEQUENCE COOL DOWN 01SEPARATE COOL DOWN VALVE Y/N NGENTLE ACTION Y/N NON TIME 212-158°F (100-70°C) 000 SEC..JA KLARENTERYES RED.NERRED.NEDJA KLARENTERYES RED.NERPress:or EDITDOWNor EDITDOWN107108FIg.107Fig.108Fig.109Fig.110020630 sec. 30 sec.0-15sec.0-15sec.ONOFF110020530 sec. 30 sec.ONOFF109