Waterlogic® Countertop Service Guide - Version 1, May 201517Performance Data SheetMODEL NAME: F-FWCU1-M-HCA-TT-XX-YY2 WATERLOGICCOUNTERTOP WATER PURIFIER WITH CYST/LEAD REMOVALFILTER FT-0006-L00-YYY AND SEDIMENT REMOVAL FILTERFT-0003-L00-YYYXX: COLOR CODE, -YY2: CUSTOMER CODEIMPORTANT NOTICEThis system, when used with FT-0006-L00-WLT 1 micron CBC cystand reduction filter, has been tested according to NSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 55 Class A and NSF/ANSI P231 for the reductionof the substances listed below.Tested using flow rate=0.5 GPM; pressure=60 psi; pH=7.5 ± 0.5; temp.=20 ± 1.0 °C.The concentration of the indicated substances in water entering the system was reducedto a concentration less than or equal to the permissible limit for water leaving the system,as specified in NSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 55 Class A and NSFANSI P231.While testing was conducted under standard laboratory conditions, actual performancemay vary.Filter Performance Data TableParameterMinumum% reductionrequirement /Max effluentconcentrationAverageInfluentChallengeEffluentAverageEffluentMaximumPercentReductionAveragePercentReductionMinimumChlorine >=50% reduction 1.90 ppm 0.02 mg/L 0.02 mg/L 98.9% 98.9%Cyst >=99.95%reduction120,000oocyst/L38oocyst/L< 50oocyst/L 99.99% 99.97%Lead(Low pH = 6.5) < 10 ug/L 144 ug/L 0.49 ug/L 1.60 ug/L 99.7% 98.9%Lead(High pH =8.5)< 10 ug/L 140 ug/L 1.47 ug/L 7.50 ug/L 98.9% 94.6%ParticulateClass I (>=0.5um to <1 um)>=85% reduction >/=10,000particles/ml288particles/ml704particles/ml 97.9% 94.9%