WL2 FW Manual Page 12 – Revision EU05-07-17INSTALLATION RAILWARNING! ALWAYS USE INSTALL RAIL. It is required to use an installation rail for theinstallation of any Waterlogic Water Treatment System. Failure to use an installation rail canresult in damage due to excessive pressures over a prolonged period of time and no additionalleak protection. Please check local water bylaws, in some countries an installation rail is a legalrequirement.CAUTION! ALWAYS INSTALL VERTICALLY. Do not install installation rail horizontally as this willaffect the performance of the water block.Water inlet – 15mm compression fittingIsolation valve – Quarter turn to isolate.Double check valve – only allows water to flow one way, no adjustmentneeded.Pressure Reducing Valve – Reduces the pressure from any high pressuredown to 3bar +/- 0.5bar. The pressure reducing valve is an essentialpart of the installation rail and ensures that the Waterlogic WaterTreatment System is not exposed to high pressures over a prolongedperiod of time.Water block – The water block will shut the flow ofwater in the event that a leak has taken place. Thisworks by measuring the velocity of water and shuttingoff water flow. Adjustment and reset can be made bypressing or turning the red dial located on the frontface of the water block.Adjustment Settings: 1.3 to 13.2 gallons(6-60Litres)*Note Every notch increases the set volume by 1.5 +/- gallons(5 +/- litres)Pressure Requirements: 10 - 125 PSI (0.7 - 8.6 bar)Ambient Temperature: 35 - 140°F (2 - 60°C)Fluid Temperature: 35 - 158°F (2 - 70°C)Flow Rate: 0.53 - 7.9 GPM (2 - 30 Lpm)Resistance to Bursting: 725.19 PSI at 77˚F (>50 bar at 25˚C)¾” to ¼” John Guest adaptor – Allows the connection of ¼” John GuestPE pipework from the install rail to the bulkhead of the machine.Open Closed