Phaser 5400 Laser Printer Service Guide 231RegistrationPurposeTo adjust the registration in the scan direction and the process direction.To Set Default Tray1. Enter Diagnostics Mode and press [1] or [5] to scroll to ìMain Menu / Test Printî.2. Ensure the paper guides are properly set to match the paper size.3. Press [2] or [6] to scroll to ìInput Trayî.4. Press [3] or [7] to scroll to the tray that you wish to be the Default Tray.5. Press [4] to set.Check1. Set the Default Tray per the above procedure.2. Ensure paper is loaded correctly and the side paper guides are properly set.3. Press [1] or [5] to scroll to ìMain Menu / Test Printî.4. Press [2] or [6] to scroll to ìPrint Patternî and press [4].5. After at least two prints complete, press the [0] key for one second to stop theprinting.6. The measurement should be made on two consecutive test patterns from each tray. Measure the distance from the top edge of the paper to the top edge of theimage (C) and measure the distance from the bottom edge of the paper to thebottom edge of the image (D). These two measurements should be equal (seeFigure 35). Measure the distance from the lead edge of the paper to the lead edge of theimage (A) and measure the distance from the trail edge of the paper to thetrail edge of the image (B). These two measurements should be equal (seeFigure 35).7. If either measurement does not meet specification perform the adjustment below.8. Repeat steps 1 through 6 for each paper tray.Adjustment1. Press [1] or [5] to scroll to ìNVM Config.î2. Enter the NVM Password in this sequence: [0], [7], [3] and [4].3. Press [2] or [6] to scroll to ìProcess Tray ëXíî or ìScan Tray ëXíî adjustment forthe desired tray. Process Tray X shifts the image from the Leading Edge to Trailing Edge (Ato B). Scan Tray X shifts the image from top to bottom (C to D).4. Press [3] or [7] one time to display the current setting.5. Press [3] or [7] again to scroll to a new setting / value.