ML501 Getting Started Tutorial www.xilinx.com 17UG228 (v1.0) August 30, 2006ML501 Demonstrations in System ACE CFRChipScope Pro ToolsLocationSystem ACE configuration address 4.From the Bootloader menu, select option 4 to start the ChipScope Pro tools demonstration.DescriptionThis demonstration contains a loadable 32-bit binary counter that can be read andcontrolled using the ChipScope Pro Virtual I/O (VIO) feature. The LEDs show the upperbits of the counter. The inputs and outputs of the counter are also shown in theChipScope Pro logic analyzer mode.Setup1. Connect the Xilinx download cable from the computer to the ML501 board.2. Open the ChipScope Pro Analyzer.3. Open the ML501_chipscope_demo.cpj file in <LAB_DIR> using File ā OpenProject.4. Establish a JTAG connection with the ChipScope Pro ILA core running on the ML501board. Click the left-most icon in the ChipScope Pro Analyzer icon bar:5. Look at the Virtual I/O (VIO) console (Figure 8, page 18). In the top-left windowlabeled Project: ml501_chipscope, scroll to the bottom and double-click on VIOconsole.You should see 32_bit_counter_count_val changing as the 32-bit counter runsat 100 MHz. Click the load button (box to the right of the signal name) to force thecounter to 0x00000000 where it resumes counting. Clicking the buttons associatedwith button_led_* turns on/off the corresponding LED on the board. Changing theDIP switches or pushing the directional buttons on the board also updates the statusvalues in the VIO console.www.BDTIC.com/XILINX