Installation 3-1 Manual 0-4809SECTION 3:INSTALLATION3.01 Site Selection• Place in a clean and dry area.• Provide adequate ventilation and fresh air sup-ply.• Ideal ambient temperature should not exceed40°C / 104°F. Temperatures exceeding that maydiminish cutting capacity or quality.• The cutting machine must be placed on an even,firm surface so that it stands firmly.3.02 Electrical Input Connections• Input voltage is 230V ± 10%, 50/60 Hz singlephase.CAUTIONCheck your power source for correct voltage be-fore plugging in or connecting the unit. Theprimary power source, fuse, and any extensioncords used must conform to local electrical codeand the recommended circuit protection and wir-ing requirements as specified in Section 2.0.3.03 Compressed Air Connection• An air compressor is required and should be con-nected to rear panel of power source by air hose.• Air pressure should be 75 psi (5.2 bar) and airshould be dry and clean.• Air flow should be 400 scfh / 6.6 scfm (188.7 lpm)minimum.ConnectAir Here InputPowerArt # A-04485DANGERDo not cut in humid or wet surroundings.• Before you maintain or replace torch parts, waitfor the post flow air cycle (approximately 10 sec-onds), to stop, then turn the machine off.• Always use original manufacturers parts. The useof aftermarket parts could result in shorter partslife and in unsatisfactory cutting results. Any war-ranty claims would be waived.NOTERepairs must be done by skilled and qualifiedpersonnel only.