5 Installation ProcedureYASKAWA ELECTRIC TOBP C730600 79C YASKAWA AC Drive Option AO-A3 Installation Manual 29n Ferrule-Type TerminalsYaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent ferrule-typeterminals with the specifications listed in Table 4 for wiring to ensure proper connections.Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.Table 4 Ferrule-Type Terminal Sizesu Terminal FunctionsTable 5 Option Terminal FunctionsFerrule-TypeTerminalWire Gaugemm2Phoenix ContactModelLmm (in)d1mm (in)d2mm (in)0.25 (24 AWG) AI 0.25 - 6YE 10.5 (13/32) 0.8 (1/32) 2 (5/64)0.34 (22 AWG) AI 0.34 - 6TQ 10.5 (13/32) 0.8 (1/32) 2 (5/64)0.5 (20 AWG) AI 0.5 - 6WH 14 (9/16) 1.1 (3/64) 2.5 (3/32)Terminal Function Signal Level DescriptionV1<1> Set the functions and output levels for terminals V1 and V2 using drive parameters. See the drive InstructionManual for directions on setting parameters.Analog voltage output 1-10 to 10 V• Analog voltage output for an external monitoringdevice <1>• Output resolution 11-bit plus sign (1/2048)• Max. load current 3 mAV2 Analog voltage output 2AC Common 0 V Common for analog voltage outputFE Ground – Used for grounding shielded linesd1 d26 mmL