2 Basic OperationsDX100 2.9 Overriding Welding Condition Function2-38156446-1CDHW04858062.9.4 Parameters for the Units to Adjust ConditionsWhen using the specific keys to adjust a condition, the units for eachcondition can be set by the following parameters.Set the multiplication of the minimum unit of each condition.Parameter Meanings InitialValueS3C1200 The units for adjusting the welding current value (When the specific key ispressed once)Min. units for the current value: 1 A, Min. units for the command value: 0.01V1S3C1201 The units for adjusting the welding current value (When the specific key ispressed consecutively)Min. units for the current value: 1 A, Min. units for the command value: 0.01V1S3C1202 The units for adjusting the welding voltage value (When the specific key ispressed once)Min. units for the voltage value: 0.1 V or 1 %, Min. units for command value:0.01 V1S3C1203 The units for adjusting the welding voltage value (When the specific key ispressed consecutively)Min. units for the voltage value: 0.1 V or 1 %, Min. units for the commandvalue: 0.01 V1S3C1204 The units for adjusting the speed (When the specific key is pressed once)Min. units: 1 cm/min1S3C1205 The units for adjusting the speed (When the specific key is pressedconsecutively)Min. units: 1 cm/min1S3C1206 The units for adjusting the weaving single amplitude (When the specific keyis pressed once)Min. units: 0.1 mm1S3C1207 The units for adjusting the weaving single amplitude (When the specific keyis pressed consecutively)Min. units: 0.1 mm1S1E51 The units for adjusting the sensing U/D condition (When the specific key ispressed once)Min. units: 1 A1S1E52 The units for adjusting the sensing U/D condition (When the specific key ispressed consecutively)Min. units: 1A1S1E53 The units for adjusting the sensing L/R condition (When the specific key ispressed once)Min. units: 0.1 A1S1E54 The units for adjusting the sensing L/R condition (When the specific key ispressed consecutively)Min. units: 0.1 A1