VAN-V19001E [V1000→GA500] 15/353-4. Differences in Terminal Size, Shape, and Wire GaugeMain circuit terminal sizes and wire gaugesThe wire gauge sizes for the GA500 described here are different from the connectable wire gauge sizes indicated in theinstruction manual for the purpose of clarifying the compatibility with the V1000.* For information on the GA500 recommended wire gauge sizes and the wire gauge sizes compliant with the Europeanstandards and the UL standards, refer to the GA500 Technical Manual.Table 9: Icons representing the screw head shapesTable 10: Differences in main circuit terminal size and wire gauge for 200 V class Note: shows an earthing terminalModelDrive capacityV1000: TypeGA500: TypeTerminalConnectablewire gauge size:mm2Terminal Screw Tighteningtorque: N-m(lbf・in)Size ShapeV10002A00012A00022A00042A0006R/L1, S/L2, T/L30.75-2 M3.5 0.8-1.0(7.1-8.9)U/T1, V/T2, W/T3-, +1, +2B1, B2⏚GA5002001200220042006R/L1, S/L2, T/L3 2Note: Change thewiring whenreplacing fromV1000.M3 0.5-0.6(4.4-5.3)U/T1, V/T2, W/T3-, +1, +2B1, B2⏚ M3.5 0.8-1.0(7.1-8.9)V10002A00082A00102A00122A00182A0020R/L1, S/L2, T/L32-5.5 M4 1.2 to 1.5(10.6-13.3)U/T1, V/T2, W/T3-, +1, +2B1, B2⏚GA500200820102012R/L1, S/L2, T/L32-5.5M3 0.5-0.6(4.4-5.3)U/T1, V/T2, W/T3-, +1, +2B1, B2⏚ M4 1.2 to 1.5(10.6-13.3)2018R/L1, S/L2, T/L3 2-5.5M41.5-1.7(13.5-15)U/T1, V/T2, W/T3-, +1, +2 2-8B1, B22-5.5⏚ 1.2 to 1.5(10.6-13.3)2021R/L1, S/L2, T/L3 2-8M41.5-1.7(13.5-15)U/T1, V/T2, W/T3 2-5.5-, +1, +2 2-8B1, B22-5.5⏚ 1.2-1.5(10.6-13.3)V1000 2030R/L1, S/L2, T/L35.5-14 M4 2.1-2.3(18.6-20.4)U/T1, V/T2, W/T3-, +1, +2B1, B2 2-5.5⏚ 5.5-14 M5 2.0-2.5(17.7-22.1)Icon Screw head shapeSlotted head (-)Hexagon socket head (width across flats: 5)