YASKAWA ELECTRIC TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement 93 Modifications from Standard Software3 Modifications from Standard SoftwareChanged Item High Frequency Software Standard SoftwareApplicable Drive Models All AllMaximum Output Frequency 1000 Hz (1167) <1><1> In order to set the frequency reference above 1000 Hz, consult the Yaskawa Application Engineering group at(800-927-5292) for application review and procedures.400 HzCarrier Frequency Max: 7 kHzC6-02: 2, B, C, FMax: 15 kHzC6-02: 1 ~ A, FDrive Current Rating Fixed at Heavy Duty (HD) ratings Depends on C6-01Drive Overload Rating Fixed at 150%/1 min. (C6-01 fixed) Depends on C6-01Control Mode Fixed at V/f (A1-02 fixed) V/f, OLV, OLV for PMDriveWorksEZ (DWEZ) No AvailableCommunication Option Kits No AvailableFrequency Setting Resolution Fixed at 0.1 Hz 0.01 Hz (less than 100 Hz)0.1 Hz (above 10 Hz)Frequency reference andoutput frequency displayunits. <2> <3>o1-03 parameter (same as b5-20)0: 0.1 Hz1: 0.01 (Max frequency 100%)2: Deleted3: User Defined (o1-10 and o1-11)o1-03 parameter (same as b5-20)0: 0.1 Hz1: 0.01 (Max frequency 100%)2: RPM3: User Defined (o1-10 and o1-11)<2> MEMOBUS/Modbus frequency reference can be set by 0.1 Hz. For 1000 Hz reference, 10000 (2710Hex) must beset to 0002Hex MEMOBUS/Modbus register.<3> Also applies to register data via MEMOBUS/Modbus RTU communication.Torque CompensationEnabled only at low speeds.Refer to New and Modified SoftwareFunctions on page 14.Constant throughout the entirefrequency range.On-Delay CompensationEnabled only at low speeds. Addition of On-Delay Compensation Selection parameter S1-01Refer to New and Modified SoftwareFunctions on page 14.Enabled throughout the entirefrequency range.Stall Prevention Level DuringAcceleration (L3-02) Maximum setting: 170% Maximum setting: 150%Deleted Functions• All OLV and OLV for PM specificparameters• All OLV and OLV for PM specific monitors• Estimation type Speed Search• High Slip Braking (HSB)• Auto-Tuning• KEB• Overexcitation DecelerationRefer to Modified Parameters on page 10.-