i.3 Mechanical InstallationThis section outlines specifications, procedures, and the environment for proper mechanical installation of the drive.u Installation EnvironmentInstall the drive in an environment matching the specifications in Table i.3 to help prolong optimum performance life.Table i.3 Drive Installation EnvironmentEnvironment ConditionsInstallation Area IndoorsAmbient TemperatureIP00/Open Type enclosure: -10 °C to +50 °C (14 °F to 122 °F)IP20/UL Type 1 enclosure: -10 °C to +40 °C (14 °F to 104 °F)Drive reliability improves in environments without wide temperature fluctuations.When using the drive in an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the airtemperature inside the enclosure does not exceed the specified levels.Do not allow ice to develop on the drive.Humidity 95% RH or less and free of condensationStorage Temperature -20 °C to +60 °C (-4 °F to +104 °F)Surrounding AreaInstall the drive in an area free from:• oil mist and dust• metal shavings, oil, water, or other foreign materials• radioactive materials• combustible materials (e.g., wood)• harmful gases and liquids• excessive vibration• chlorides• direct sunlight.Altitude 1000 m (3281 ft.) or lower, up to 3000 m (9843 ft.) with deratingVibration10 to 20 Hz: 9.8 m/s2 (2o0028 to 2o0248, 4o0011 to 4o0414)20 to 55 Hz: 5.9 m/s2 (2o0028 to 2o0081, 4o0011 to 4o0077)20 to 55 Hz: 2.0 m/s2 (2o0104 to 2o0248, 4o0096 to 4o0414)Orientation Install the drive vertically to maintain maximum cooling effects.NOTICE: Avoid placing peripheral devices, transformers, or other electronics near the drive, as the noise created can lead to erroneousoperation. Take proper steps to shield the drive from noise if such devices must be used in close proximity.NOTICE: Prevent foreign matter such as metal shavings and wire clippings from falling into the drive during installation. Failure to complycould result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary cover beforestart-up, as the cover will reduce ventilation and cause overheat.u Installation Orientation and SpacingNOTICE: Install the drive upright as illustrated in Figure i.5. Failure to comply may damage the drive due to improper cooling.Figure i.5 Correct Installation OrientationNOTICE: Install the drive upright as specified in the manual. Failure to comply may damage the drive due to improper cooling.n Single Drive InstallationFigure i.6 shows the installation distance required to maintain sufficient space for airflow and wiring.i.3 Mechanical InstallationYASKAWA ELECTRIC TOEP C710636 11E Z1000U HVAC MATRIX Drive Quick Start Guide 15