78 FT-1802M OPERATING MANUAL41 RESUMEFunction: Selects the Scan Resume mode.Available Values: BUSY / HOLD / 3SEC / 5SEC / 10SECDefault: BUSYBUSY: The scanner will hold until the signal disappears, then will resumewhen the carrier drops.HOLD: The scanner will stop when a signal is received, and will not restart.3SEC/5SEC/10SEC: The scanner will hold for the selected resume time, then resume whetheror not the other station is still transmitting.42 RF SQLFunction: Adjusts the RF Squelch threshold level.Available Values: S1 - S9 / OFFDefault: OFF43 RPTFunction: Sets the Repeater Shift direction.Available Values: –RPT / + RPT / SIMPDefault: SIMP44 RVRTFunction: Enables/disables the “Priority Channel Revert” feature.Available Values: ON / OFFDefault: OFF45 S SRCHFunction: Selects the Smart Search Sweep mode.Available Values: SINGLE / CNTNUEDefault: SINGLESINGLE: The transceiver sweeps the current band once in each direction, starting on thecurrent frequency. All channels where activity is present (up to 15 in each direc-tion) are loaded into the Smart Search memories. Whether or not all 31 memo-ries are filled, the search stops after one sweep in each direction.CNTNUE: The transceiver makes a sweep in each direction as with the “SINGLE” mode,but if all 31 channels are not filled after the first sweep, the radio continuessweeping until they are all filled.46 SHIFTFunction: Sets the magnitude of the Repeater Shift.Available Values: 0.00 - 99.95 MHzDefault: 0.60 MHz“SET ” (MENU) M ODEMENU S ELECTION D ETAILS