26FTM-3100R Operating ManualReset Procedure/CloneReset ProcedureIn some instances of erratic or unpredictable operation, the cause may be corruption ofdata in the microprocessor (due to static electricity, etc.). If this happens, resetting themicroprocessor may restore normal operation. Note that all memories will be erased ifyou do a complete microprocessor reset, as described below.Microprocessor ResettingTo clear all memories and other settings to factory defaults:1. Turn the radio OFF.2. Press and hold the [TXPO], [MHz(SETUP)], and [V/M(MW)] keys while turning theradio on. The “ALL RESET PUSH V/M KEY” notation will scroll on the display.3. Press the [V/M(MW)] key momentarily to reset all settings to their factory defaults(press any other key to cancel the Reset procedure).Set Mode ResettingTo reset the Set (Menu) mode settings to their factory defaults, while leaving other set-tings unchanged:1. Turn the radio OFF.2. Press and hold the [TXPO] and [MHz(SETUP)] keys while turning the radio on. The“SET MODE RESET PUSH V/M KEY” notation will scroll on the display.3. Press the [V/M(MW)] key momentarily to reset the Set (Menu) mode settings to theirfactory defaults (press any other key to cancel the Reset procedure).CloneThe FTM-3100R includes a convenient “Clone” feature, which allows the memory andconfiguration data from one transceiver to be transferred to another FTM-3100R.This can be particularly useful when configuring a number of transceivers for a publicservice operation.Note: For details, refer to the Advanced Manual (download from the Yaesu website).