AV-S70/NX-SW70AV-S70/NX-SW707 DSP DIAG MODE (Self-diagnosis)Use the remote controller supplied as an accessory to select the menu.1. Procedure for starting DSP DIAGReferring to TEST PROGRAM MODE in the previous section, select/execute “04 DSP Diag”.When “04 DSP Diag” is executed, the current input name appears on the display followed by “Video” > “Sel.1to9 Key”.(The DSP indicator keeps flashing.)2. Procedure for selecting Main menu and Sub-menuUsing [1] through [9] keys on the remote controller, select the main menu. Soon the sub-menu will appear on the display.Then, select the sub-menu. Every time the selected key (on the remote controller) is pressed, the sub-menu on the displaychanges.No. Main menu (Display)1 Analog through Analog Thr.2 DSP through Dsp Through3 AC-3 through AC-3 Through4 Pro logic Pro Logic5 Speakers set Speakers Set6 Effect off Effect Off7 Manual test Manual Test8 No function9 DIAG cancelSub-menu (Display)MAIN BYPASS A.T.M.BypassDSP 0dB A.T. DSP 0dBYSS908-SRAM DspT.908SRAMYS908 DspT.YSS908DSP FULL BIT DspT.FullBitStatus (Binary) AC3 Analo2/0CENTER LARGE ProL.CenterLEFFECT OFF ProL.Eff.OffMAIN : SMALL 0dB Sp.MainS 0dBMAIN : LARGE 0dB Sp.MainL 0dBLFE/BASS : MAINCENTER : NONE Sp.Lfe:M C:NLFE/BASS : MAIN Sp.LfeBass:MLFE/BASS : SWFR Sp.Lfe:SwfrCENTER : NONE Sp.Cent:NoneCENTER : SMALLREAR : SMALL Sp.Ce:S Re:SEFFECT OFF Effect OffALL M.Test AllMAIN L M.Test LeftCENTER M.TestCenterMAIN R M.Test RightREAR R M.Test RearRREAR L M.Test RearLLFE M.Test Lfe3. Procedure for canceling DIAGThere are two methods for cancellation of DIAG.a. Turn off the power by pressing the [POWER] key of the main unit or the remote controller.b. Press the [9] key of the remote controller. (The normal mode will be restored.)www . xiaoyu163. comQQ 376315150 992894298TEL 13942296513 992894298051513673QQTEL 13942296513 QQ 376315150 892498299TEL 13942296513 QQ 376315150 892498299http://www.xiaoyu163.comhttp://www.xiaoyu163.com