8-1– +ELECELECTRICALSWITCH INSPECTIONSWITCH INSPECTIONUse a pocket tester to check the terminals for conti-nuity. If the continuity is faulty at any point, replacethe switch.NOTE:• Set the pocket tester to “0” before starting a test.• When testing the switch for continuity the pockettester should be set to the “× 1 Ω” range.• When checking the switch turn it on and off a fewtimes.Pocket tester:90890-03112, YU-03112-CINSPECTING A SWITCH SHOWN IN THEMANUALThe terminal connections for switches (main switch,handlebar switch, engine stop switch, light switch,etc.) are shown in a chart similar to the one on theleft. This chart shows the switch positions a in thecolumn and the switch lead colors b in the top row.For each switch position, “ ” indicates theterminals with continuity.The example chart shows that:There is continuity between the “Brown and Red”leads when the switch is set to “ON”.There is continuity between the “Brown and Red”and between “Brown/White and Red/White” leadswhen the switch is set to “START”.OFFONSTARTBr R Br/W R/WRBrR/WBr/WbaSWITCH INSPECTION