5331838-YTG-A-0317Johnson Controls Unitary Products 3All dimensions are in inches and are subject to change without notice.Overall height is from bottom of base pan to top of fan guard.Overall length and width include screw heads.PHYSICAL AND ELECTRICAL DATAMODEL YXV24B21S YXV36B21S YXV48B21S YXV60B21SUnit Supply Voltage 208-230V, 1 60HzNormal Voltage Range 1 187 to 252Minimum Circuit Ampacity 17.4 25.7 28.6 33.9Max. Overcurrent Device Amps 2 30 40 45 50CompressorType Scroll Scroll Scroll ScrollRated Load 12.8 19.2 20.8 25.0Locked Rotor 23.0 35.0 35.0 50.0Crankcase Heater (Stator Heat) Yes Yes Yes YesHS Kit Required with TXV N/A N/A N/A N/AFan Diameter Inches 24 24 26 26Fan MotorRated HP 1/8 1/4 1/3 1/3Rated Load Amps 1.4 1.7 2.6 2.6Nominal RPM 1025 1025 975 1050Nominal CFM 3500 3900 4800 5300CoilFace Area Sq. Ft. 23.82 23.82 28.80 31.2Rows Deep 1 1 2 2Fins / Inch 22 22 18 18Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8Vapor Line Set OD (Field Installed)3 3/4 3/4 7/8 7/8Unit Charge (Lbs. - Oz.) 4 7 - 8 7 - 6 14 - 9 15 - 1Charge Per Foot, Oz. 0.62 0.62 0.67 0.67Operating Weight Lbs. 194 205 264 2701. Rated in accordance with AHRI Standard 110-2012, utilization range “A”.2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.3. For applications with non-standard vapor line sizes, see the “Applications & Accessories” section of this Technical Guide.4. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-tract the amount of refrigerant, using the difference in actual lineset length (not the equivalent length) multiplied by the per foot value.&% $$DIMENSIONSUnitModelDimensions(Inches)Refrigerant ConnectionService Valve SizeA B C Liquid VaporYXV24B21S 40-1/4 35-1/2 323/83/4YXV36B21S 40-1/4 35-1/2 32YXV48B21S 43-1/4 38-1/4 34-1/2 7/8YXV60B21S 46-1/2 38-1/4 34-1/2