343615-YTG-A-0807Unitary Products Group 3PRODUCT NOMENCLATURED Y 048 N04 A 2 A AA 2 0 1 2 4 AD = A/C, Single Pkg., R-22Product CategoryAirflowD = Direct Drive/Motorized DamperB = Direct Drive/Single Input EconomizerA = Direct DriveProduct Generation2 = Second GenerationC00 = Cooling Only. Suitable for FieldInstalled Electric HeatHeat Type and Nominal Heat CapacityN04 = 40 MBH Output Aluminized Steel, 1 Stage (036)N06 = 60 MBH Output Aluminized Steel, 1 Stage (048)N08 = 80 MBH Output Aluminized Steel, 1 Stage(036, 060)N10 = 100 MBH Output Aluminized Steel, 1 Stage(048, 060)D06 = 60 MBH Output Aluminized Steel, 2 Stage(036, 048, 060)D10 = 100 MBH Output Aluminized Steel, 2 Stage(036*, 048, 060)S04 = 40 MBH Output Stainless Steel, 1 Stage (036)S06 = 60 MBH Output Stainless Steel, 1 Stage (048)S08 = 80 MBH Output Stainless Steel, 1 Stage(036, 060)S10 = 100 MBH Output Stainless Steel, 1 Stage(048, 060)T06 = 60 MBH Output Stainless Steel, 2 Stage(036, 048, 060)T10 = 100 MBH Output Stainless Steel, 2 Stage(036*, 048, 060)*(D, T)10 = 92 MBH Output on 036 ModelsE05 = 5 KWE07 = 7 KWE10 = 10 KWE15 = 15 KWE20 = 20 KWE30 = 30 KWGas Heat OptionsElectric Heat Options036 = 3.0 TonNominal Cooling Capacity048 = 4.0 Ton060 = 5.0 TonProduct IdentifierY = 14.0 SEERVoltage1 = 208/230-1-602 = 208/230-3-604 = 460-3-605 = 575-3-60Product StyleA = Style AA = No Options InstalledInstallation OptionsB = Option 1C = Option 2D = Options 1 & 2E = Option 3F = Option 4G = Options 1 & 3H = Options 1 & 4J = Options 1, 2 & 3K = Options 1, 2, & 4L = Options 1,3 & 4M = Options 1, 2, 3, & 4N = Options 2 & 3P = Options 2 & 4Q = Options 2, 3, & 4R = Options 3 & 4S = Option 5T = Options 1 & 5U = Options 1, 3, & 5V = Options 1, 4, & 5W = Options 1, 3, 4, & 5X = Options 3 & 5Y = Options 4 & 5Z = Options 3, 4 & 51 = Disconnect2 = Non-Pwr'd Conv. Outlet3 = Smoke Detector S.A.4 = Smoke Detector R.A.5 = Pwr'd Conv. OutletOptionsSS Drain PanConfiguration Options (not required for all units)These four digits will not be assigned until a quote is requested, or an order placed.CPC Controller, DFS, APSJohnson Controller, DFS, APSHoneywell Controller, DFS, APSNovar Controller, DFS, APSSimplicity IntelliComfort ControllerSimplicity IntelliComfort Controller w/ModLinc2" Pleated filtersBAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)Any Combination of Additional Options that Don’t Have an Option Code Pre-assignedAA = NoneStandard CabinetAB = Phase MonitorAC = Coil GuardAD = Dirty Filter SwitchAE = Phase Monitor & Coil GuardAF = Phase Monitor & Dirty Filter SwitchAG = Coil Guard & Dirty Filter SwitchAH = Phase Monitor, Coil Guard & Dirty Filter SwitchAS = Bottom Drain ConnectionRC = Coil Guard & American FlagTA = Technicoat Condenser CoilTJ = Technicoat Evaporator CoilTS = Technicoat Evaporator and Condenser CoilAdditional OptionsHinged Filter Door & Toolless Access Cabinet3-5 Ton Sunline Magnum™ Model Number NomenclatureBA = Hinged Filter Door & Toolless Access PanelsBB = Phase Monitor, Hinged Filter Door & ToollessAccess PanelsBC = Coil Guard, Hinged Filter Door & ToollessAccess PanelsBD = Dirty Filter Switch, Hinged Filter Door &Toolless Access PanelsBE = Phase Monitor & Coil Guard, Hinged FilterDoor & Toolless Access PanelsBF = Phase Monitor & Dirty Filter Switch, HingedFilter Door & Toolless Access PanelsBG = Coil Guard & Dirty Filter Switch, Hinged FilterDoor & Toolless Access PanelsBH = Phase Monitor, Coil Guard & Dirty Filter Switch,Hinged Filter Door & Toolless Access PanelsZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will belocated in digits 15-18.