036-21339-001 Rev. C (0602)Unitary Products Group 3- = Not applicableCOOLING CAPACITY - With Air Handler CoilsUNIT MODELAIR HANDLER COIL1MODELCOOLINGMODEL ELECTRIC 2HEAT KW W RATEDCFMTOTALCAPACITYSENSIBLECAPACITYSEERW/O TXVSEER+ TXV 3 EER1 PH 13 SEER AC WITH N-AH / G2FDH1RD018S06 N1AHB08 2,5,8,10 17 G2FD024S17 600 20.8 14.6 - 13.75 12.45H1RD024S06 N1AHB08 2,5,8,10 17 G2FD024S17 800 23.8 16.6 - 13.30 12.00N1AHB08 5,8,10,15,19 17 G2FD030S17 800 24.2 17.0 - 13.60 12.20H1RD030S06 N1AHB12 5,8,10,15,19 17 G2FD030S17 1000 29.2 20.4 - 13.25 11.65N1AHB12 5,8,10,15,19 17 G2FD036S17 1000 29.4 20.4 - 13.25 11.65H1RD036S06 N1AHB12 5,8,10,15,19 17 G2FD036S17 1200 33.6 24.2 - 13.00 11.60N1AHB12 5,8,10,15,19 17 G2FD046S17 1200 34.8 24.9 - 13.00 11.80H1RD042S06 N1AHC16 5,8,10,15,20 21 G2FD042S21 1400 40.5 27.8 - 13.30 11.60N1AHC16 5,8,10,15,20 21 G2FD048S21 1400 41.0 28.5 - 13.50 11.80H1RD048S06N1AHC16 5,8,10,15,20 21 G2FD048S21 1600 45.5 31.3 - 13.25 11.90N1AHD20 8,10,15,20,25,30 24 G2FD060S24 1600 46.5 31.7 - 13.50 12.10N1AHD20 8,10,15,20,25,30 24 G2FD061H24 1600 47.0 32.2 - 13.70 12.20H1RD060S06 N1AHD20 8,10,15,20,25,30 24 G2FD060S24 1900 53.5 37.1 - 13.25 12.00N1AHD20 8,10,15,20,25,30 24 G2FD061H24 2050 54.5 39.1 - 13.25 12.101 PH 13 SEER AC / N1VS - VARIABLE SPEEDH1RD018S06 N1VSB12 5,8,10,15,19 17 G2FD024S17 600 21.4 15.5 - 15.50 13.90H1RD024S06 N1VSB12 5,8,10,15,19 17 G2FD024S17 825 24.4 17.4 - 15.00 13.35N1VSB12 5,8,10,15,19 17 G2FD036S17 825 25.4 18.2 - 15.75 14.05H1RD030S06 N1VSB12 5,8,10,15,19 17 G2FD036S17 1000 30.4 21.7 - 14.25 13.05N1VSB12 5,8,10,15,19 17 G2FD046S17 1000 31.0 22.1 - 15.50 13.40H1RD036S06N1VSB12 5,8,10,15,19 17 G2FD036S17 1200 34.0 24.6 - 13.75 12.35N1VSB12 5,8,10,15,19 17 G2FD046S17 1200 35.4 25.5 - 14.00 12.70N1VSC16 5,8,10,15,20 21 G2FD048S21 1200 36.4 26.0 - 14.50 13.25H1RD042S06 N1VSC16 5,8,10,15,20 21 G2FD048S21 1380 42.0 28.9 - 14.50 12.70H1RD048S06N1VSC16 5,8,10,15,20 21 G2FD048S21 1600 46.5 31.9 - 13.75 12.60N1VSD20 8,10,15,20,25,30 24 G2FD060S24 1600 47.0 32.2 - 14.00 12.70N1VSD20 8,10,15,20,25,30 24 G2FD061H24 1600 47.5 32.7 - 14.00 12.90H1RD060S06 N1VSD20 8,10,15,20,25,30 24 G2FD060S24 1780 53.5 36.3 - 13.50 12.35N1VSD20 8,10,15,20,25,30 24 G2FD061H24 1780 54.5 37.0 - 13.75 12.601 PH 13 SEER AC / F2RP / RC / FP / FC / FV 4,5H1RD018S06F2RP/F2FP018 5,8,10 18 -- 600 19.8 14.6 - 13.20 12.05F2RP/F2FP024 5,8,10 18 -- 600 21.0 15.0 - 14.00 12.60F2RC/F2FC024 5,8,10 18 600 20.8 14.6 - 13.80 12.50H1RD024S06F2RC/F2FC024 5,8,10 18 -- 800 23.8 16.6 - 13.25 11.90F2RC/F2FC030 5,8,10,15 18 -- 800 23.8 16.6 - 13.30 11.90F2RP/F2FP024 5,8,10 18 -- 800 23.8 16.6 - 13.30 11.95F2RP/F2FP030 5,8,10,15 18 -- 800 24.2 17.0 - 13.60 12.20H1RD030S06F2RC/F2FC030 5,8,10,15 18 -- 1000 29.6 20.4 - 13.25 11.65F2RC/F2FC036 5,8,10,15, 19 21 -- 1000 29.8 21.3 - 14.00 12.05F2RP/F2FP030 5,8,10,15 18 -- 1000 29.6 20.5 - 13.25 11.75F2RP/F2FP036 5,8,10,15, 19 21 -- 1000 30.0 21.2 - 13.50 11.90H1RD036S06F2RP/F2FP036 5,8,10,15, 19 21 -- 1200 34.2 24.5 - 13.00 11.75F2RP/F2FP042 5,8,10,15 24 -- 1200 34.4 24.5 - 12.80 11.55F2RP045 5,8,10,15 24 -- 1200 35.8 26.1 - 13.50 12.25F2RP048 5,8,10,15 24 -- 1200 35.6 25.5 - 13.00 11.70H1RD042S06F2FP/F2FP042 5,8,10,15 21 -- 1400 40.0 27.7 - 13.00 11.40F2FP045 5,8,10,15 24 -- 1400 42.0 29.0 - 13.80 12.10F2FP048 10,15,20,25 24 -- 1400 41.0 28.3 - 13.00 11.50H1RD048S06F2FP045 10,15,20,25 24 -- 1565 46.5 31.4 - 13.50 12.15F2FP048 10,15,20,25 24 -- 1565 45.5 30.8 - 13.00 11.70F2FP060 10,15,20,25 24 -- 1600 46.0 31.2 - 12.75 11.50F2FV060 10,15,20,25 24 -- 1600 47.0 32.1 - 14.00 12.65H1RD060S06 F2FP060 10,15,20,25 24 -- 1900 53.0 36.7 - 13.00 11.60F2FV060 10,15,20,25 24 -- 1900 53.5 36.3 - 13.50 12.35Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.Cooling MBH based on 80∞F entering air temperature, 50% RH, and rated air flow.EER (Energy Efficiency Ratio) is the total cooling output in BTUís at 95∞F outdoor ambient divided by the total electric power in watt-hours at those conditions.SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUís during a normal annual usage period for cooling divided by the total electric powerinput in watt-hours during the same period.1 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.2 Single phase units require single phase 2HK heaters.3 TXV = Use 1TV700 series kit.4 To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.5 FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard. |
Related manuals for York H*RD018 THRU 060
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine