4INSTALLATION DIAGRAMINSTALLATION OF THE OUTDOOR UNITThe outdoor unit must be installed in such a way,so as to prevent short circuit of the hot dischargedair or obstruction to the smooth air flow. Pleasefollow the installation clearances shown in thefigure. Select the coolest possible place whereintake air temperature is not greater than theoutside air temperature (maximum 45°C).Indoor UnitFront panelOutdoor Unit50mm or more from walls(on both sides)30mm or more from ceiling Caulk pipehole gapwith putty.Cut thermal insulationpipe to an appropriatelength and wrap it withtape, making sure that nogap is left in the insulationpipe’s cut line.Wrap the insulation pipe withthe finishing tape from bottomto top.M4 x 12LAir filterAir filterAir-Purifying Filterwith bacteriostaticvirustatic functionFilter frameTabAir-Purifying Filter with bacteriostaticvirustatic function (2)Service lid Opening service lidService lid is opening/closing type. Opening method1) Remove the service lidscrews.2) Pull out the service liddiagonally down in thedirection of the arrow.3) Pull down.Dimension A B CMinimum Distance, 300 300 500mm (in) (11.8) (11.8) (19.7)Installation clearancesObstacleReturn airService accessObstacleObstacleReturn airDischarge airAB CNote: If there is any obstacle higher than 2m, orif there is any obstruction at the upper part of theunit, please allow more space than the figureindicated in the above table.250mm from wall