13AMBIENTTEMPERATUREINDICATOR(THERMOMETER)SET TEMPERA-TURE INDEX TEMPERATURESETTING DIALAUTOCONTVENTLEVEL"A" LEVEL"B"CALREFPARO10 15 20 25 30..... ..... ..... .......... ..... ..... .....SET TEMPERA-TURE INDEXSET TEMPERA-TURE INDEXDIAL TO SET THE WINTERTEMPERATURE (HEATING)DIAL TO SET THE SUMMERTEMPERATURE (COOLING)FANAUTO ON HEAT COOL10 15 20 25HEAT COOLCLEVEL "B"LEVEL "A"OFFAMBIENT TEMPERATUREINDICATOR(THERMOMETER)Instructions for useGeneral informationThe start up and automatic temperature setting is carried outby means of the ambient thermostat, at 24 volts, speciallydesigned for these units.Depending upon the model of your air conditioner, same willbe controlled by the corresponding thermostat. The thermo-stat models may be: T-11 (one cooling phase and oneheating phase), T-12 (one cooling phase and two heatingp h a s e s ) ,T-22 (two cooling phases and two heating phases). Theinstruction manual will allow you to become familiar with theoperation of any and all of these.Ambient thermostatThe thermostat for the SOC air conditioners are designedto give a correct ambient temperature control, and have allnecessary controls for start up, stopping, selection andautomatic temperature setting. It is equipped with a thermo-metric indicator that permanently shows the ambient tem-perature of the room being conditioned.T-11 and T-12 thermostatStarting process for the T-11 and T-12 thermostatsThe thermostat has three basic operating modes:a) For ventilating only:Lever A set to CONT.Lever B set to OFF.Dial at any setting.b) Summer air conditioning (cooling):Lever A set to CONT or AUTO.Lever B set to REF.Dial set to the desired temperature index.c) Winter air conditioning (heating):(with heating battery, optional accessory)Lever A set to CONT or AUTO.Lever B set to CAL.Dial set to the desired temperature index.In the "OFF" position the cooling unit is inoperative. Whenlever A is set to "CONT", only the fan operates. At the "REF"or "CAL" and "AUTO" settings, the fan starts to operatesimultaneously with the compressor or the electric heater, ifinstalled (optional accessory), in accordance with the ther-mostat index and the ambient temperature. The unit iscompletely inoperative when lever A is set to "AUTO" andlever B to "OFF".Starting process for the T-22 thermostatThe thermostat has three basic operating modes:a) For ventilating only:Lever A set to ON.Lever B set to OFF.Dial at any setting.b) Summer air conditioning (cooling):Lever A set to ON.Lever B set to COOL.Dial set to the desired temperature index.c) Winter air conditioning (heating):(with heating battery, optional accessory)Lever A set to ON.Lever B set to HEAT.Dial set to the desired temperature index.In the "OFF" position the cooling unit is inoperative. Whenlever A is set to "ON", only the fan operates. At the "COOL"or "HEAT" and "AUTO" settings, the fan starts to operatesimultaneously with the compressor or the electric heater, ifinstalled (optional accessory), in accordance with the ther-mostat index and the ambient temperature. The unit iscompletely inoperative when lever A