c Air Swing - SwitchTo Auto Deflect the Conditioned Air from Left to Right & Back with Vertical Air Deflectors, push theSwitch to the ON position and OFF position to stop. If you require the Air to be deflected to oneparticular direction, then Switch ON the Air Swing switch and OFF the switch when the Deflectorsare in the required direction. Some models are Installed with an illuminated Switch and It will emitlight to indicate ON position.d Indicator Light.When provided in the unit, indicates Unit Operation.e Exhaust Lever - Exhaust Air Damper.Exhaust Lever is either Iocated on Front or Top of the Control Panel. When in OPEN position,odours, foul smell, cigarette smoke can be exhausted to the outside atmosphere.f Air DeflectorsHorizontal Air Deflectors are provided on the Plastic Front Panel. These can be lipped as in [L] offig M to deflect Air to the desired direction (Up, Straight & Down or a combination of any two).Notes :1 When you switch over to cool or Heat Operation / Mode, ensure that the fan is running.2 Wait 3 Minutes before restarting or resetting from Heat / Cool mode to fan and between heat & coolmode3 If the Compressor Stops while turning the Temperature Dial, Clock or Counter Clock wise, wait for3 Minutes before turning back to Counter Clock or Clockwise respectively.4 In LO-COOL, LO-HEAT modes, or when the unit is switched OFF, Occasionally slight refrigerantFlow Noise from the Refrigerating cycle will be heard. This noise is not an Abnormal operation.5 A click Noise will be heard in Electrical Heater Models when the Heater Thermostat functions. ThisNoise is not an abnormal operation.6 This room air conditioner should not be used when the outside temperature is below 680 F (20 0 C) inCool Operation / Mode.7 The air deflectors and the Front Panel should not be covered with anything in heating operation.The distance between the air deflectors and obstacles should be over 20” (50cm) minimum.8 Slight rubbing sound may be heard when the Vertical or Horizontal Deflectors are moving duringheating operation. This is not abnormal.4 Maintenancea Air Filter1 The Air filters most of the dust from the room air, So it should at least be cleaned every 15 days orwhen air filter gets shocked with dust. If not cleaned the Filter will get chocked and the Airflow willreduce. This will decrease the Cooling or Heating efficiency of the Air conditioner.2 To remove the Air Filters, gently press at Point [A] & [B] as shown in Fig. N to unlock the Return AirGrille Insert and then open and hold the Grills at the UP “U” position. Hold the Filter Handle, gentlyrelease it from the Front Panel by slightly lifting it up and taking it out.3 Wash the Filter with clean Water (if possible with running tap water) and replace it after gentlyshaking it to remove the moisture. Don’t use water above 95 F (35 0 C) for washing and reinstall theairfilters after cleaning 8