5.2.5 Pump drive wiringThe pump drive must be connected to its motor terminal board in the delta (see wiring diagram).U1UVWV1W1W2V2U2Delta connectionAfter entering the motor parameters (see the chapter "Parameterisation of the ZAdyn4CA HY"), theturning direction of the pump must be checked. For this purpose, start a travel upwards in inspectionmode (see the chapter "Travelling in inspection mode"). If the pump runs backwards (pay attention tosound of pump), the turning direction must be changed. To do so, there are the following possibilities:• Swapping two motor phases (e.g. U and V)• Changing the parameter Start-up/MO_DR5.3 Motor temperature monitoring (X-MT)InformationThe X-MT connection terminal is a standard part of the ZAdyn4CA HY.InformationThe detection of over temperature of the motor doesn't cause a drive interruption. The current drivewill be completed.If an over temperature of the motor will be detected at stop, there is no further drive possible.The temperature monitoring is carried out according to IEC 61800-5-1:2003-02 (switching point at3500 Ω)The following sensor types can be used:• PTC thermistor (PTC according to DIN 44082)• Temperature sensor KTY84-130• Thermal circuit breakerThe used sensor has to be parametrized in the menue Monitoring/P1P2!Monitor|-" P1P2 PTC|-" PTCMotor temp. monitorP1P2X-MTP1P2M3~PEV WU(P1)(P2)Temperature monitoring connection() terminal designation of connectorQuick Start Guide ZAdyn4CA HY Electrical installationR-TBA16_01-GB 1845 Index 003 Part.-No. 00163456-GB11/28