A BCDEA. Green and YellowB. 3 amp fuseC. BrownD. Cord clampE. BlueThe wires in the cord are coloured as follows:Green and yellow - EarthBlue - NeutralBrown - LiveWARNING! A cut off plug insertedinto a 13 amp socket is a seriousshock hazard. Ensure that the cut offplug is disposed of safely.REPLACEMENT OF THE CONNECTIONCABLEThe replacement of electric cable mustbe carried out exclusively by theservice force centre or by personnelwith similar competencies, inaccordance with the currentregulations.To replace the connection cable useonly H03V2V2-F T90 or equivalenttype. Make sure that the cable sectionis applicable to the voltage load andthe working temperature. The yellow/green earth wire (B) must beapproximately 2 cm longer than thelive and neutral wire (A).A B1. Connect the green and yellow (earth) wire tothe terminal which is marked with the letter 'E',or the earth symbol , or coloured green andyellow.2. Connect the blue (neutral) wire to the terminalwhich is marked with the letter 'N' or colouredblue.3. Connect the brown (live) wire to the terminalwhich is marked with the letter 'L'. It mustalways be connected to the network phase.There must be no cut or stray strands of wirepresent. The cord clamp must be correctlyattached to the outer sheath.ASSEMBLY1.2.13