Zero BNP 162 Manual
BNP 162, 164 and 166 TUMBLE BLAST CABINETS Page 8© 2017 CLEMCO INDUSTRIES CORP. www.clemcoindustries.com Manual No. 14429 Rev. F3. Timer: Sets duration of the blast cycle. Turn thedial to set the blast duration between 1 minute and 60minutes. Once the timer is set, begin blasting by pushingthe "System Start" button. Blasting automatically stopswhen the timer times-out. The time must be reset afterevery blast cycle.4. Barrel Jog: The exhauster must be on toenable the switch. Pressing the momentary switchrotates the barrel. Use it to empty the barrel of residualmedia that remains in the barrel after blasting and toposition the barrel door to the front of the cabinet forloading and unloading parts. The barrel continues torotate as long as pressure is maintained on the switch.5. Door Interlock: The door interlock disablesblasting when the door is open. To enable blasting, thedoor must be closed and the door interlock switchengaged.4.1.2 Variable speed controls, Figure 7Refer to Section 4.1.1 for constant speed controls.1. System Start: Pushing the button starts theexhauster and tumble barrel. Other controls will notoperate unless the exhauster is running.2. System Stop: Pushing in the button stops theexhauster and all other controls.3. Timer: Turn the dial to set the blast durationbetween 1 minute and 60 minutes. Once the timer is set,begin blasting by pushing the "Sequence Start" button.Blasting automatically stops when the timer times-out.Once the timer is set it does not require resetting afterblasting, unless the blasting duration changes.4. Barrel Jog: The exhauster must be on beforeengaging the switch. Pressing the momentary switchrotates the barrel. The barrel continues to rotate as longas pressure is maintained on the switch.5. Door Interlock: The door interlock disablesblasting when the door is open. To enable blasting, thedoor must be closed and the door interlock switchengaged.6. Sequence Start: Once the timer is set (the timerdoes not require resetting unless the blasting durationchanges) and the gun switch is ON, blasting starts whenthe switch is pushed in. If the gun switch is OFF, alltumble operations except blasting starts when thesystem switch is engaged.Figure 77. Sequence Stop: Pushing the button stops theblast and tumble cycle. If the timed cycle was notcompleted, the blast cycle will continue for the remainingtime if the sequence start button is pressed.8. Blast Guns Switch: The switch engages anddisengages the blast guns. If the switch is toward ON,blasting starts when the system start button is pressed.If the switch is OFF, all tumble operations exceptblasting are ON. NOTE: The barrel with continue torotate, which will empty abrasive from within the barrel.Do not turn the blast guns OFF during the blastcycle if it will cause part-on-part damage occurringwhile tumbling.9. Speed Control: Controls the rotation speed ofthe tumble barrel.Optional Media Blow-off: A blow-off timer is situatedinside the variable speed panel, but it does not operateany controls unless the blow-off option was requestedwhen the cabinet was ordered. If the cabinet includesthe option, blow-off automatically begins at the end ofthe blast cycle. Adjust the timer to the length of time theblow-off is to remain ON. Blow-off automatically stops atthe end of the timed cycle. If media remains in the barrelor on the parts after the cycle, increase blow-off time.NOTE: If the blow-off option was not requested, setthe timer to 0 and leave it there. Because the timer isincluded and wired into the circuit, the blow off optionmay be added later. Refer to the wiring schematicstowed inside the panel.48351269 7 |
manualsdatabase
Your AI-powered manual search engine