Page 14 of 40 802005UK - Residential (Boiling),chilled and sparkling installation instructions - Aug 2015 - v2.01HydroTap®G4 Arc & Cube - tap installationThe HydroTap Arc/Cube has a spout that may be fixed in one of 6 angular positions (depending on theposition of the rotary control) and fixed in one of two height positions. The spout is fixed and does not swivel.To reduce the risk of scalding, Position *A should not be selected with any of the boiling water units.(See fig. 1.8).1.6 Configuring the tap• Remove the 2 x spout locating screws and lower the spout to expose the plastic spring clip.Note The plastic spring clip has two internal dimples that may be positioned in the 6 upper or 6 lower,pre drilled holes in the spout (see diagram below & figs. 1.7 & 1.8)• To reposition the spout, gently spread the plastic spring clip to release the dimples from the spoutholes. When released, slide the clip on the spout so that it ends up between the two rows of holes.• Rotate the plastic clip on the spout to orient the dimples, so they are in line with the newly selectedholes.Note When determining which of the 6 holes are required for the new spout height and orientation,check the new plastic clip position will clear the undercut and that the USB lead will not be pinched,when assembled.• Slide the plastic clip up/down to engage with the selectedholes, making sure the two dimples engage simultaneouslywith the two selected holes.Note The clip will not fit correctly if one dimple engagesbefore the other. Both dimples must engage at the same time.• With the clip fitted to the newly selected holes,carefullyraise the spout (ensure the USB lead is a neat fit in theundercut and is located between the open ends of theclip) until the clip locating holes are in line with the spoutlocating screws.• Replace the 2 x locating screws.• If mounting on an uneven surface, apply a light smearingof silicon sealant on the o-rings to ensure a watertight fit.(See fig. 1.9).• Pass the assembly (ensuring upper o-ring, base ring andlower o-ring are in place) through the Ø35mm hole andposition the tap so it discharges into the sink.• Fit the lower rubber seal to the threaded extension.• Secure the tap in position with the metal washer and nut.Spout locatingscrews (2)Undercutfor loomLower locatingpositionsPlasticspring clipUpper locatingpositionsClip locatingholes (2)DimplesPlasticspring clip