Page 8 0f 20 Zip Hydro Tap Installation and Operating Instructions - 81467 - April 20061. Position the Font template (provided) on the bench area. Ensure theposition you select is within the length of the supply tube and USB cablefixed to the Tap Head Assembly. These cannot be extended.2. Check again for correct positioning.The supply hoses must have constantfall back to the tank assembly. Cut the holes as shown on the template.3. Once holes are cut, locate the Font base in position, from the underside,lightly tighten the securing rod with the nut and washer provided.4. Apply a light smear of silicon sealant to the underside of the black basering, this will provide a water tight seal against the Font base whenclamped. * Ensure the plastic spacer is corectly located under the Font.5. Now take the Tap Head Assembly. Feed the hoses and USB cable throughthe Font base, then through the plastic spacer that sits under the fontbase but on the bench top. This stops warping of the base plate. Ensurethe Tap spout is directly centered over the Font drain. Fit the “SpiderClamp”, nut and washer onto the “All Thread”. Have all the supply tubesand USB cable located evenly between the “Spider Clamp” legs. Whensatisfied with the positioning, tighten the fixing nut with the Tube Spannerprovided in the kit.6. Tighten the securing pin so the Font base is flush with the bench top.NOTE: The fixing nut above the drain elbow can be loosened to correctlyposition the direction of the elbow. Ensure when the re-positioning iscomplete the nut is re-tightened to ensure a water tight seal.7. Connect a drain hose (22mm ID) from the Font base outlet elbow to theclosest drain trap spigot available. If a spigot is not available use the snapon spigot and worm drive clamps supplied in the kit. (Instructions anddiagrams are supplied in the kit ref:81496).8. Ensure the positioning of the snap-on spigot is on the “sink” side of thetrap and not the “waste” side. Once positioned, a hole (13mm ID) willneed to be drilled to provide waste access to the drain line. The snap-onunit will require suitable sealant to keep it water tight against the wastepipe. Finish by fitting the worm drive clamps tightly on either side of thespigot and fitting worm drive clamps to either end of the drain hose. Thedrain hose from the Font must have constant fall9. Connect the Tap head Assembly supply hoses and vent as per theinstructions contained in the installation procedure section of thisdocument.Font installation procedureTap assyhole 35mmHole required for Fontrecess 108mmFixing studDrain elbowView from undersideCut a 10mmslot for studBlackPlasticSpacerSee note 4.Note: A stainless steel washer issupplied to go in between theSpider Clamp and the undersideof the benchtop. See location asshown.SpiderClampFixing nutS/S WasherTapAll-thread rodBenchtopFontSpacerUnder Font *