dbCAN: remote control via dbCAN (CAN-Bus)/ROPE C.In 2-Way Active mode indicated as "CAN " and the "dbCAN Id" e.g. 7.63 in the main screen.In Dual channel or Mix Top/Sub mode indicated withthe "dbCAN Id" e.g. 7.63 in the main screen.dbCAN IdSetting the "dbCAN identifiers [n].[nn]". The first digit represents theCAN sub net. Eight sub-nets can be defined (values 0 to 7). Using thetwo digit device ID for each sub-net 63 devices can be defined (values01 to 63).LockSelecting "Lock" and pushing the encoder enters the sub-menu.Lock nowPushing the encoder switches the device into "Lock" mode according tothe mode selected below and exits the sub-menu "Lock". In 2-WayActive Mode a locked device is indicated by " " in the Main screen.ModeSelecting "Mode" and pushing the encoder toggles between twooptions to protect the device against unintentional operation.Press 2s: prevents accidental operation by locking the frontpanel controls.Password: password protection that prevents operation byunauthorized persons.ShowSelecting "Show" and pushing the encoder allows two different screensto be displayed when the device is locked.Main Screen: switch to the "Main screen".Levels Screen: switch to the "Levels screen".Selecting "Password" and pushing the encoder enters the sub-menu"Edit Password".D12 Software manual (Firmware V2.x.x) (5.2EN) Page 21 of 36Lock Press 2sPasswordLockBackLock nowMode Press 2sD12 Stage rightJ12-3.0dB-3.0dBHFC LFC EQ 0.01Active0.3msDCANC -5Sub net 0 to 7Device Id 01 to 63dbCAN Id 7. 01dbCAN Id 0. 01dbCAN Id 7. 63dbCAN Id 7. 01Show Main Screen