82 H-ClassStandard Calibration (continued)Step Action Displayed Message CommentG Observe the calibrationresult. CALIBRATION COMPLETECalibration wassuccessful. If WARNING LOWBACKING is displayed,calibration was successful(for possible messagessee Section 5.1).HPress ESC then EXIT toreturn to READY.When calibrating gap orreflective media, press andhold the FEED Key until atleast one label is output.CALIBRATION COMPLETEFollowed by...READYThe printer is now readyfor use.5.2.2 Advanced Entry CalibrationAdvanced Entry is an alternate calibration method for special-case media types, wheresensor readings are taken using different sampling algorithms and from a list of thesereadings the best algorithm is selected for manual entry into the database. Advanced Entry Calibration should be used only when Standard Calibration provesunsuccessful. Also, before proceeding, ensure that the ADVANCED MENU is enabled(see Section 4.2.4) and that the SENSOR TYPE is selected (see Section 4.2.1).Calibrate the Media Sensor using the steps below: