Operating instructionsW3G800-CG02-03Translation of the original operating instructions3.2 Nominal dataMotor M3G150-FFPhase 3~Nominal voltage / VAC 400Nominal voltagerange / VAC380 .. 480Frequency / Hz 50/60Type of data definition mlSpeed / min-1 830Power input / W 1420Current draw / A 2.2Max. back pressure / Pa 155Max. ambienttemperature/ °C60ml = Max. load · me = Max. efficiency · fa = Running at free aircs = Customer specs · cu = Customer unitSubject to alterations3.3 Data according to ErP directiveInstallation category AEfficiency category StaticVariable speed drive YesSpecific ratio* 1.00* Specific ratio = 1 + pfs / 100 000 PaActual Request2013Request2015Overall efficiency ηes / % 45.9 30.3 34.3Efficiency grade N 51.6 36 40Power input Ped / kW 1.24Air flow qv / m³/h 14305Pressure increase total psf / Pa 133Speed n / min-1 835Data definition with optimum efficiency.The ErP data is determined using a motor-impeller combination in a standardisedmeasurement configuration.3.4 Technical featuresMass 41.6 kgSize 800 mmSurface of rotor Coated in blackMaterial of electronicshousingDie-cast aluminium, coated in blackMaterial of blades Die-cast aluminiumMaterial of wall ring Sheet steel, pre-galvanised and blackplastic-coatedMaterial of guard grille Steel, phosphated and coated in blackplasticNumber of blades 5Blade angle 0°Direction of air flow "V"Direction of rotation Clockwise, seen on rotorType of protection IP 54Insulation class "F"Humidity class F4-1Mounting position Shaft horizontal or rotor on bottom; rotoron top on requestCondensate dischargeholesRotor-sideOperation mode S1Motor bearing Ball bearingTechnical features - PFC, passive- Control input 0-10 VDC / PWM- Over-temperature protectedelectronics / motor- Alarm relay- Integrated PID controller- Input for sensor 0-10 V or 4-20 mA- Output for slave 0-10 V- RS485 ebmBUS- Line undervoltage / phase failuredetection- Motor current limit- Soft start- Output 10 VDC, max. 10 mA- Output 20 VDC, max. 50 mATouch current acc.IEC 60990 (measuringnetwork Fig. 4, TNsystem)<= 3.5 mAElectrical leads Via terminal boxMotor protection Reverse polarity and locked-rotorprotectionProtection class I (if protective earth is connected bycustomer)Product conformingto standardCEApproval CSA C22.2 Nr.77; EAC; UL 2111; VDEFor cyclic speed loads, note that the rotating parts of the deviceare designed for maximum one million load cycles. If you havespecific questions, contact ebm-papst for support.3.5 Mounting data; Secure the mounting screws against accidentally coming loose (e.g.by using self-locking screws).Strength class formounting screws8.8You can obtain additional mounting data from the product drawing ifnecessary.3.6 Transport and storage conditions; Use the device in accordance with its protection type.Max. permissibleambient motor temp.(transp./ storage)+80 °CMin. permissibleambient motor temp.(transp./storage)-40 °CItem no. 50176-5-9970 · Revision 82539 · Release 2014-05-08 · Page 5 / 12ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com