ebm-papst W3G800-NE57-53 Operating Instructions Manual
Operating instructionsW3G800-NE57-53Translation of the original operating instructions; Soiling of the impeller can cause vibration that will shorten the servicelife of the fan.; Severe vibration can destroy the fan.; In such cases, switch off the fan immediately and clean it.; The preferred method of cleaning is dry cleaning, e.g. usingcompressed air.; Do not use aggressive cleaning agents!NOTEDamage to the device during cleaningMalfunction possible→ Do not clean the device using a high-pressure cleaner.# Donot use acid, alkali or solvent-based cleaning agents.→ Do not use any pointed or sharp-edged objects forcleaning.; Completely remove any cleaning agents used.; If severe corrosion is visible on load-bearing or rotating parts, switchoff the device immediately and replace it.; Repair of load-bearing or rotating parts is not permitted!; Operate the fan for 2 hours at maximum speed so that any water thathas ingressed can evaporate.; If cleaning does not eliminate vibrations, the fan may need to berebalanced. To have it rebalanced, contact ebm-papst.; The fan is equipped with maintenance-free ball bearings. The lifetimelubrication of the ball bearings is designed for a service life of 40,000hours.; If bearing replacement is necessary after that period, contact ebm-papst.; Adapt the maintenance intervals to the actual level of dust exposure.6.2 Safety inspectionNOTEHigh-voltage testThe integrated EMC filter has Y capacitors. The tripping currentis exceeded when AC testing voltage is applied.→ Test the device with DC voltage when you perform thelegally required high-voltage test. The voltage to be usedcorresponds to the peak value of the AC voltage required bythe standard.What to check How to check How often What action?Contactprotectioncover forintactness ordamageVisual inspection At least every6 monthsRepair orreplacement ofdeviceDevice fordamage toblades andhousingVisual inspection At least every6 monthsReplacement ofdeviceFastening thecablesVisual inspection At least every6 monthsFastenFastening theprotective earthterminalVisual inspection At least every6 monthsFastenInsulation ofcables fordamageVisual inspection At least every6 monthsReplace cablesCondensationdrainage holesfor clogging,where necessaryVisual inspection At least every6 monthsOpen holesWelds for crackformationVisual inspection At least every6 monthsReplace deviceAbnormalbearing noiseacoustic At least every6 monthsReplace device6.3 DisposalFor ebm-papst, environmental protection and resource preservation aretop priority corporate goals.ebm-papst operates an environmental management system which iscertified in accordance with ISO 14001 and rigorously implementedaround the world on the basis of German standards.Right from the development stage, ecological design, technical safetyand health protection are fixed criteria.The following section contains recommendations for ecological disposalof the product and its components.6.3.1 Country-specific legal requirementsNOTECountry-specific legal requirementsAlways observe the applicable country-specific legalregulations with regard to the disposal of products or wasteoccurring in the various phases of the life cycle. Thecorresponding disposal standards are also to be heeded.6.3.2 DisassemblyDisassembly of the product must be performed or supervised byqualified personnel with the appropriate technical knowledge.The product is to be disassembled into suitable components for disposalemploying standard procedures for motors.WARNINGHeavy parts of the product may drop off. Some of theproduct components are heavy. These componentscould drop off during disassembly.This can result in fatal or serious injury and material damage.→ Secure components before unfastening to stop them falling.6.3.3 Component disposalThe products are mostly made of steel, copper, aluminum and plastic.Metallic materials are generally considered to be fully recyclable.Separate the components for recycling into the following categories:● Steel and iron● Aluminum● Non-ferrous metal, e.g. motor windings● Plastics, particularly with brominated flame retardants, in accordancewith marking● Insulating materials● Cables and wires● Electronic scrap, e.g. circuit boardsOnly ferrite magnets and not rare earth magnets are used in externalrotor motors from ebm-papst Mulfingen GmbH & Co. KG.; Ferrite magnets can be disposed of in the same way as normal ironand steel.Electrical insulating materials on the product, in cables and wires aremade of similar materials and are therefore to be treated in the samemanner.Item no. 55671-5-9970 · ENU · Change 218409 · Approved 2021-01-15 · Page 13 / 14ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com |
Related manuals for ebm-papst W3G800-NE57-53
ebm-papst W3G800-KE57-51 Operating Instructions Manual
ebm-papst W3G800-KE57-51 Operating Instructions Manual
ebm-papst W3G800-NS26-73 Operating Instructions Manual
ebm-papst W3G800-NU21-06 Operating Instructions Manual
ebm-papst W3G800-NB86-41 Operating Instructions Manual
ebm-papst W3G800-NB86-43 Operating Instructions Manual
ebm-papst W3G800-NS26-71 Operating Instructions Manual
ebm-papst W3G800-NU21-08 Operating Instructions Manual
ebm-papst W3G800-CH03-03 Operating Instructions Manual
ebm-papst W3G400-IC22-53 Operating Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine