Torso1. Chest compressions: The manikin presents the correctanatomical landmarks for external chest compressions.2. Defibrillation: The manikin is equipped with two defibrillationconnectors and four lead connectors for use with AEDs ormanual defibrillators. The ECG signal can also be monitoredacross these connectors. Using the remote control, the instructorcan select the “ignore defib” function to control whether or notthe defibrillation shall result in conversion to a perfusing rhythm.Paddle adapters are supplied for use with manual defibrillators.Note: Defibrillation must be performed over the two defibconnectors only as shown in figure 1.3. Stomach: The manikin is equipped with a stomach and pressurevalve system that allows stomach distension at inspiratorypressures of more than 25 cmH2O. To deflate press gently onthe stomach as shown in figure 2.4. Power Supply: The manikin is intended to operate from batterypower. An AC power adapter is included in the event the userprefers not to use battery power (110 – 240V AC).Connect the power adapter to the manikin as shown in figure 3.Remote ControlCommunication between the remote control and the manikinis based on low power radio frequency (RF) communication.If the remote control device is used in an environment whereRF communication is not desirable, or where interference fromother sources makes the remote control device inoperable, it isrecommended to use the cable connection between the remotecontrol and the manikin. Using the direct cable connectiondisables the RF circuits in both the remote control and the manikin.For use of this cable see later section.Overview of the RemoteControl DeviceA. LCD display: Displays statusand operation information.B. Quick execution buttons:Function keys.The function of eachbutton is labeled on the displayabove the button.C. Navigation keys:Use keys to navigateand select functionson the display.D. OK/Select key:Use this key to activateselected functions.E. Cancel/Back key:Go back from sub menus without any changes.F. Numerical keys: Use these keys to enter numerical data or toselect numbered parameters. Can also be used as alphanumericalkeys to enter file and event-namesG. Menu/Setup: Enter Setup Menu.H. Scenario: Use this button to start a scenario.I. Shift keyJ. On/Off key: Press once to turn the unit on.Press again to turn the unit off.For Remote Control to properly recognize the manikin1. Turn on the manikin by pressing the “On/Off” button located onthe right side of the manikin’s torso as shown in figure 5.2. Turn on the remote control by pressing the On/Off key(indicated by the letter J in remote control figure 4). The remotecontrol will automatically detect the manikin and set the initialparameters accordingly. A splash screen will be displayed for afew moments until the main display is shown.Note: If an error message appears stating “no reception”, make surethat the manikin is turned on.IHGBCDEFJA5Figure 1Figure 2Figure 5Figure 4Figure 3 On/Off