ELECTRICAL CONNECTIONWARNING:: Danger to life due to livecomponents!During all electric operation, disconnect the machinefrom the network and verify the absence ofpower.The machine and its accessories must be connectedin accordance with local regulations, by aCompany specialized in electrical installationsand authorized by competent authorities.Before connecting the machine,check to make sure the voltageoutlet of the mains is the same asthe voltage specified on the dataplate of the machine.A main switch must be installed betweenthe mains and the machine. This safetymeasure also requires that the minimumdistance between the switch contacts is atleast 3 mm and the disconnection on allpoles according to EN 60204 (VDE 113).Fuses on the main switch must be 20 A.The mains must be wired to be able tohandle the current drawn by themachine.The system must also be providedwith a proper ground lead in accordancewith the existings norms. The electric cablemust be of the following type H07RN-F.For the right choice of the cross sectionarea refer to the following table:mod. Volt totalpower(kW)Currentintensity max(A)Cable(mm²)LP-6-8-ek 400/3electric 13 20 2,5steam 4 8 2,5PLP31-38-ek400/3electric 26 38 10steam 6 12 2,5The electrical safety of this equipment isonly assured if it is connected as follows.It is necessary to connect the equipment toan effective ground installation, as specifiedby the electrical safety regulations in force.Chack that this basic requirement iscomplied with and, in case of doubt, ask fora careful check of the installation by aqualified personal.In addition, the equipment shall be part ofan equipotential system, the effectivenessof which should be checked according tothe regulations in force.The connection should be made at thescrew marked by the respective labellocated on the equipment back side ( ).L630180LPPL-Ingresso cavoP-Connessione allacassetta elettrica150170MOD.PT1500-LP31-38MOD.PT850-LP6-8DIS-CAVO-PTTHE MACHINE SHALL BECONNECTED WITH AN EFFECTIVEGROUND CLAMP.The manufacturer declines anyresponsibility for any damagescaused by lack of an effectiveground installation.