ELECTRICAL CONNECTIONBefore connecting the machine,check to make sure the voltageoutlet of the mains is the same asthe voltage specified on the dataplate of the machine.A main switch must be installed betweenthe mains and the machine. This safetymeasure also requires that the minimumdistance between the switch contacts is atleast 3 mm and the disconnection on allpoles according to EN 60204 (VDE 113).Fuses on the main switch must be 20 A.The mains must be wired to be able tohandle the current drawn by themachine.The system must also be providedwith a proper ground lead in accordancewith the existings norms. The electric cablemust be of the following type H07RN-F.For the right choice of the cross sectionarea refer to the following table:mod. Volt totalpower(kW)Currentintensitymax (A)Cable(mm²)PT850 400/3electric 13 20 2,5steam 4 8 2,5PT1500 400/3electric 26 38 10steam 6 12 2,5The electrical safety of this equipment isonly assured if it is connected as follows.It is necessary to connect the equipment toan effective ground installation, asspecified by the electrical safety regulationsin force.Chack that this basic requirement iscomplied with and, in case of doubt, ask fora careful check of the installation by aqualified personal.In addition, the equipment shall be part ofan equipotential system, the effectivenessof which should be checked according tothe regulations in force.The connection should be made at thescrew marked by the respective labellocated on the equipment back side ( ).L630180LPPL-Inlet cableP-Connection tothe electric box150170MOD.PT1500MOD.PT850THE MACHINE SHALL BECONNECTED WITH AN EFFECTIVEGROUND CLAMP.The manufacturer declines anyresponsibility for any damagescaused by lack of an effectiveground installation.