17TROUBLE CAUSE REMEDYWater in ice bin. 1. Coldplate drain is obstructed. 1. Remove splash plate and drip tray to obtainaccess to drain tubes and clear accordingly.Noisy/cavitating carbon-ator pump.1. Insufficient incoming water supply pressure.2. Loose pump coupling.1. Verify incoming supply water pressure tocarbonator pump is min. of 25 PSI (0.172MPA), max. of 50 PSI (0.345 MPA). Checkstrainer for cleanliness.2. Tighten set screw on pump coupling.Off Taste in Soda. 1. Leaking water check valve, allowing carbonat-ed water to back into supply line.1. Dismantle and clean check valve. ReplaceO-ring, if torn or distorted.Valves inoperable. 1. Loss of Power. 1. Check power supply to see if plugged in. Checktransformer circuit breaker. Check main powercircuit breaker, 110V.TROUBLE CAUSE REMEDYBIB pump does not op-erate when dispensingvalve is opened.1. Out of CO2, CO2 not turned on, or low CO2pressure.2. Out of syrup.3. BIB connector not tight.4. Kinks in syrup or gas lines.1. Replace CO2 supply, turn on CO2 supply,or adjust CO2 pressure to 70-80 PSI (0.483-0.552 MPA).2. Replace syrup supply.3. Fasten connector tightly.4. Straighten or replace lines.BIB pump operating, butno flow.1. Leak in syrup inlet or outlet line.2. Defective BIB pump.1. Replace line.2. Replace BIB pump.BIB pump continues tooperate when bag isempty.1. Leak in suction line.2. Leaking o-ring on pump inlet fitting.3. Defective syrup BIB pump.1. Check BIB connector, if still leaking then re-place line.2. Replace o-ring3. Replace defective pump.BIB pump fails to restartafter bag replacement.1. BIB connector not on tightly.2. BIB connector is stopped up.3. Kinks in syrup line.1. Tighten BIB connector.2. Clean out or replace BIB connector.3. Straighten or replace line.BIB pump fails to stopwhen dispensing valveis closed.1. Leak in discharge line or fittings.2. Empty BIB.3. Air leak on inlet line or bag connector.1. Repair or replace discharge line.2. Replace BIB.3. Repair or replace.Remote Syrup Pump TroubleshootingTo prevent possible harm to the environment from improper disposal, recycle the unitby locating an authorized recycler or contact the retailer where the product waspurchased. Comply with local regulations regarding disposal of the refrigerant andinsulation.Dispenser Disposal