G. Follow the same procedures to set the fill volume for the remaining valves.NOTESince the volume settings are unique to each valve, each valve can have four different dispensevolumes. Lemonade in valve position 1, for example, could have a different dispense volume(i.e., “SMALL” , “MEDIUM” , etc.) than Orange Juice in valve position 2.2.7 CLEANING AND SANITIZING INSTRUCTIONSFor optimum dispenser performance and highest drink quality, please follow the instructions listedbelow for cleaning your dispenser. The instructions are also shown on the inside front cover of theDispenser.CAUTIONDO NOT USE ANY POWDERS OR ABRASIVE CLEANING COMPOUNDS THAT WILL DAMAGEFINISH.A. Daily1. Turn the dispenser to FLUSH Mode.2. Flush each valve until clear water only is dispensed.3. Remove and wash drip tray and cup rest in warm, soapy water using a mild detergent. Rinsethoroughly with clean, warm water and reinstall drip tray and cup rest to dispenser.4. Wipe down any areas where concentrate may have spilled or beverages splashed.5. If doors were opened to wipe soiled areas, close the doors.6. Ensure the drain tube into the drip tray is properly seated.7. Follow the Loading procedures in the ON Mode.WARNINGREMOVE SANITIZING SOLUTION FROM DISPENSER AS INSTRUCTED. RESIDUALSANITIZING SOLUTION LEFT IN SYSTEM COULD CREATE HEALTH HAZARD.CAUTIONDO NOT SOAK NOZZLES IN CHLORINE SOLUTION OVERNIGHT. THIS WILL CAUSENOZZLES TO SWELL AND PLASTIC WILL BEGIN TO DETERIORATE.B. Every Two Weeks1. Turn key switch to “FLUSH MODE”, flush each valve of dispenser until clear water flowsfrom the nozzle.2. Open door and lift up on the check valve (yellow elbow) to remove it from the Minute Pak ®container.3. Remove Minute Pak container from dispenser and refrigerate.74. Remove nozzles (see Figures 14 and 15). Wash thoroughly with warm, soapy water usinga mild detergent (see Figure 16). Rinse thoroughly with clean, warm water and replace.DO NOT SOAK NOZZLES IN CHLORINE SOLUTION OVERNIGHT. THIS WILL CAUSENOZZLES TO SWELL AND PLASTIC WILL BEGIN TO DETERIORATE.5. Using a funnel, fill each specially marked sanitizing container up to the top with COOLchlorinated sanitizing solution (Diversol CX, or equivalent), minimum 100 PPM availablechlorine, but not to exceed 200 PPM; place sanitizing container in dispenser.Figure 14 Figure 15 Figure 16 Figure 17