Electrical RequirementsAny permanent electrical installation must comply with the latestI.E.E. Regulations and local electricity company regulations. Foryour own safety a qualified electrician or contractor who is on theroll of the National Inspection Council for Electrical InstallationContracting (NICEIC) should undertake the electrical installation.Electrical Connection.Before connecting the mains supply ensure that the mains voltagecorresponds to the voltage on the rating plate inside the cookerhood.WARNING: THIS APPLIANCE MUST NOT BE EARTHED.The cooker hood is supplied with a 2-core mains cable and mustbe connected to the electricity supply via a double pole switchhaving a 3mm minimum contact gap on each connector.For UK onlyA Switched Fused Connection Unit to BS 1363 Part 4 is arecommended.The fuse must be rated at 3 Amps.The wires in the mains lead are coloured in accordance with thefollowing code:Brown = L - LiveBlue = N - NeutralThe connection point must be placed in a position adjacent to theappliance so as to be readily accessible for an engineer in theevent of a breakdown.Disconnect the cooker hood from the mains supply beforecarrying out any kind of maintenance or cleaning.17In more detail...GB IETechnical and legal information