May be subject to change page 7 af 25Review of the menusMenus in the CTS 600 controlCTS 600 control has 12 menus.The control will have the main menu as starting point, (the menu in the full-drawn frame). Fromhere it is possible to go through the other menus via pq.Allows for a low ventilation level at a low outside air temperature.Main menu: displays operating status.Press ESC to return to the main menu.Operating mode (heat, auto, cool), temperatures, fan speed, type of unit andsoftware version.Alarm display and reset.Alarm log containing the latest 16 alarms.SHOWALARMSPage 10SHOWPage 13AUTO W/1>2< 19°CPage 9USERPage 14 Options: exhaust, inlet, ventilation, OFF. The function selected is activated via aswitch or pressure.15Page10-09-13TM.. 12:10Date and time settings. The time and date must be reset if the system has beenwithout power for more than 24 hours. Summer and winter time must also be setmanually.Page 16 Weekly program can be set to ON or OFF. When the program is active, 1, 2or 3 is displayed in the main menu.SELECTWEEKPROGRAMCOOLINGPage 19 Enables you to choose a higher ventilation level when the system is coolingby means of an open bypass damper.Page 20Page 21Page 22Page 23AIREXCHANGEAIRFILTERTEMP.CONTROLLANGUAGEENGLISHThe controls are factory set to activate a filter alarm every 90 days. The alarmis reset in the VIEW ALARMS menu.Enables you to set the minimum temperature allowing for the bypass damperto close. Maximum injection temperature can be set for a heating element.Select the required language: English, German, French, Swedish,Danish, Norwegian, Finnish, CzechHEATINGPage 18 The system has a heating surface installed. The heating surface can bechosen ON/OFF. Frost-protection is still active when OFF is chosen.SURFACEDATAFigure 4: Menu headlines