Ecodesign data Comfort 200 TopSEC* average climate - 38.1 kWh/(m2.a)SEC* cold climate - 76.8 kWh/(m2.a)SEC* warm climate - 13.3 kWh/(m2.a)SEC-Class AType Residential ventilation unitType of drive Variable speed driveType of heat recovery system Recuperative (counterflow heat exchanger)Thermal efficiency of heat recovery 89 %Maximum flow rate 308 m3/h (100 Pa)Electric power input of fan drive, including any motor control equipment, atmaximum flow rate 77.6 WSound power level (LWA) 56 dB(A)Reference flow rate 0.060 m3/s (215.6 m3/h)Reference pressure difference 50 PaSPI 0.33 W/(m3/h)Central demand control 0.85Maximum internal leakage 0.17 %Maximum external leakage 0.34 %Visual filter warningA yellow light flashes on the user panel when filters need changing. Tomaintain the performance and energy efficiency of the unit it is veryimportant to change filters regularly.Disassembly instructions www.nilan.dk* Specific energy consumptionAEC - annual electricity consumption 343 kWh/år (100 m2)AHS** average climate 4603 kWh (100 m2)AHS** cold climate 9004 kWh (100 m2)AHS** warm climate 2081 kWh (100 m2)** Annual heating savedComfort 200 Top (English) BY NILAN11