Show dataIt is possible to read off relevant data for Comfort units.Show data↳ Operating state Description: Shows the operating setting in which the unit isrunning.↳ Bypass Description: Shows whether the bypass damper is open or closed.↳ T2 Supply air Description: Shows the supply air temperature. If an after-heatingelement has been installed, T7 will be shown instead.↳ T3 Extract air / Room Description: Shows the room temperature as an average of theentire house.↳ T4 Discharge Description: Shows the discharge air temperature.↳ T7 Supply air Description: Shows the supply air temperature provided an after-heating element has been installed. Otherwise T2 willbe shown.↳ T8 Outdoor air Description: Shows the outdoor temperature before reaching thepre-heating element.↳ T9 Water heating element Description: Shows the temperature in the water after-heatingelement.↳ Air humidity Description: Shows the current air humidity in the house.↳ CO2 Description: Shows the current CO2 level in the house (only ifinstalled).↳ Supply air fan Description: Shows the level at which the supply air fan isoperating.↳ Extract air fan Description: Shows the level at which the extract air fan isoperating.↳ Unit information Description: Select "Unit information" for more information.↳ Unit type Description: Shows the name of the product the software has beenset to work with.↳ Software version Description: Shows the installed software version.↳ Panel software Description: Shows installed software version on the panel.Comfort 252 / 302 Top / Polar (English) BY NILAN13