Ecodesign specification Comfort CT150SEC* average climate - 42.7 kWh/(m2.a)SEC* cold climate - 82.1 kWh/(m2.a)SEC* warm climate - 17.5 kWh/(m2.a)SEC-Class A+Type Residential ventilation unitType of drive Variable speed driveType of heat recovery system Recuperative (counterflow heat exchanger)Thermal efficiency of heat recovery 91.9 %Maximum flow rate 175 m3/h (100 Pa)Electric power input of fan drive, including any motor control equipment, atmaximum flow rate 55.7 WSound power level (LWA) 49 dB(A)Reference flow rate 0.034 m3/s (122,5 m3/h)Reference pressure difference 50 PaSPI 0.163 W/(m3/h)Central demand control 0.85Maximum internal leakage 0.19 %Maximum external leakage 0.35 %Visual filter warningA yellow light flashes on the user panel when filters need changing. Tomaintain the performance and energy efficiency of the unit it is veryimportant to change filters regularly.Disassembly instructions www.nilan.dk* Specific energy consumptionAEC - annual electricity consumption 192 kWh/year (100 m2)AHS** average climate 4681 kWh (100 m2)AHS** cold climate 9157 kWh (100 m2)AHS** warm climate 2117 kWh (100 m2)** Annual heating saved12