Ret til ændringer forbeholdes Side 15 af 30Air exchangeIn the ”Air exchange” menu it is possible to adjust 4 steps of ventilation speed (air volume). Inletand exhaust is to be adjusted individually at each level.The inlet speed can be adjusted to a minimum and the exhaust can be adjusted to both a maxi-mum and a minimum.It is possible to delay the starting of the fan in order to give time to the register to open.Use of the CTS602 panel:- press ESC to go one step back in the menu- press qp to move up or down in a menu or to adjust anactivated menu- press ENTER to activate a menu- press ENTER to confirm a menu- press OFF to turn off the unit- press ON to turn the unit onCENTRALHEATINGAIREXCHANGEENTERSERVICE ENTERDEFROSTINLETCONTROLTEMP.CONTROLPRESETOFFRESTARTOFFROOMCONTROLHOTWATERThe lowest permissibleventilation step for fresh air/inlet(0-2)The lowest permissibleventilation step for outlet/exhaust(1-2)INLETMIN 0EXHAUSTMIN 1EXHAUSTMAX 4The highest permissibleventilation step for outlet/exhaust(3-4)INLET23%INLET>2 < 40%INLET>3 < 65%EXHAUST>1 < 25%EXHAUST>3 < 70%EXHAUST>4 < 100%INLET>4 < 100%EXHAUST>2 < 45%Each ventilation step can be setas a percentage of maximum fanspeed.MANUALOFF>1 <MODBUSADR 30AIRQUALITYDATALOGINTV 10Figure 9: The "Air exchange" menu