13FIGURE 7 – Tool DisplayFAIL LED(Red)PASS LED(Green)Zeroreading Manual resetOPERATING INSTRUCTIONSWARNING: KEEP HANDS CLEAR OF THE REACTION BAR.WARNING: WHEN USING THIS TOOL IT MUST BE SUPPORTED AT ALL TIMES INORDER TO PREVENT UNEXPECTED RELEASE IN THE EVENT OFFASTENER OR COMPONENT FAILURE.TighteningNOTE: Ensure ‘SET UP INSTRUCTIONS’ have been followed.1. Fit the Pneutorque® with the correct size impact or high quality socket to suit fastener.TIP: For added safety it is recommended to secure the socket to the drive square.This is often achieved using a pin and O ring, see socket manufacturer for guidance.2. Ensure shut-off torque has been set for current fastener.3. Ensure the clockwise / counter-clockwise selector is correctly set.4. Press to zero the reading.5. Rotate the handle into a convenient position relative to the reaction bar. Fit the tool onto the fastener tobe tightened with the reaction bar adjacent to the reaction point. See Figure 8.6. Adopt a suitable posture to counteract normal or unexpected movement of the tool due to reactionforces.7. Squeeze the trigger partially to bring the reaction bar into contact with the reaction point.8. Fully press trigger and keep fully pressed until tool shuts off, then release trigger.If the trigger is not fully pressed full torque may not be applied to the fastener.9. The trigger must be released before the tool resets to prevent a further torque application.